Rheem 871 Series Owner's Manual And Installation Instructions page 35

Continuous flow gas water heater
Table of Contents

Advertisement

4.
Set the bath fill water volume
Press the BATH FILL VOLUME
BATH FILL VOLUME
The first press of either the BATH FILL VOLUME
(up button)
(down button) will display the last selected
bath fill water volume setting in the bath fill water
volume display panel and the bath fill indicator light
will glow.
While the bath fill water volume is displayed, each
subsequent press of the BATH FILL VOLUME
(up button)
(down button) will change the water volume
setting by 10 litres.
When the BATH FILL VOLUME
pressed and the water volume setting is increased,
the voice prompt will sound;
"caution, bath fill water volume has been increased, bath may overflow"
When the BATH FILL VOLUME
decreased, the voice prompt will sound;
"bath fill water volume has been decreased"
Pressing the BATH FILL VOLUME
continuously will scroll the water volume setting.
A maximum volume of 990 litres and a minimum volume of 10 litres can be set. The maximum
volume of 990 litres is achieved in 10 litre increments up to 500 litres, then 990 litres is the next
setting.
The selected bath fill water volume will be displayed and the bath fill indicator light will glow on all
Deluxe controllers.
The bath fill water volume display panel will go blank
and the bath fill indicator light will go out 3 seconds
after the last press of either of the volume
adjustment buttons.
The set volume will be remembered when the
BATH FILL button is next pressed "on".
Close the front panel on the Deluxe controller.
5.
Turn on the Bath Fill mode
6.
Press the BATH FILL button.
On all Deluxe controllers:
The BATH FILL operating light will glow.
The bath fill temperature setting will appear on
the temperature display panel.
The bath fill water volume will appear on the
bath fill water volume display panel.
The bath fill indicator light will glow.
The voice prompt will sound;
"please set bath water volume and bath
temperature, then open the hot water tap"
(up button) or the
(down button).
or
the
BATH FILL
or
BATH FILL
(up button) is
(down button) is pressed and the water volume setting is
TEMPERATURE CONTROL – DELUXE
1 2 0
VOLUME
BATH (l)
BATH FILL
BATH FILL 
VOLUME
VOLUME
B1
1.
2.
Bath Fill
Bath
Bath
Water
Fill 
Volume
Temp
Set Bath Fill Water Volume
and Temperature 
Hot Water
1.
ON/OFF
Press 
(up button) or BATH FILL VOLUME
 
1 2 0
BATH (l)
BATH FILL
 
1 2 0
BATH (l)
BATH FILL
35
ACTIVE
°C
4 0  
ON/OFF 
"caution,
bath fill water
BATH FILL 
volume has been
TEMPERATURE 
Rheem
increased,
bath may overflow"
or
"bath fill water
3.
5. 
7. 
Bath Fill 
volume has been
completed 
BATH FILL
BATH FILL 
Press Bath
(automatic) 
Press Bath 
Bath Fill Button 
Fill Button 
Fill Button 
decreased"
(Red light flashes) 
(Red light on)
(R
ed light off) 
4. Open hot tap
6. Close hot tap 
2.
3. 
4. 
ACTIVE
Adjust 
Open hot 
Light on
Temperature 
tap 
(down button)
ACTIVE
°C
4 0  
ON/OFF 
Rheem 
ACTIVE
°C
4 0  
ON/OFF 
"please set
bath water volume
and
bath temperature,
Rheem 
then open the
hot water tap"

Advertisement

Table of Contents
loading

Table of Contents