This water heater must be installed and serviced by a qualified person.
Please leave this guide with a responsible officer.

Advertisement

Table of Contents
loading

Summary of Contents for Rheem 872 Series

  • Page 1 Owner’s Guide Installation Instructions Continuous Flow Gas Water Heater 872 series 627 models This water heater must be installed and serviced by a qualified person. Please leave this guide with a responsible officer.
  • Page 2 Rheem Australia Pty Ltd and Rheem New Zealand Limited are the suppliers of the Rheem range of continuous flow gas water heaters, manufactured in Japan by Paloma Co., Ltd., a world leader in water heater technology and manufacture.
  • Page 3: Table Of Contents

    Rheem warranty. We recommend you read pages 7 to 17, and the terms of the Rheem warranty on pages 4 to 6. The other pages are intended for the installer but may be of interest.
  • Page 4: Warranty

    The decision of whether to repair or replace a faulty component is at Rheem’s sole discretion. If you require a call out and we find that the fault is not covered by the Rheem warranty, you are responsible for our standard call out charge. If you wish to have the relevant component repaired or replaced by Rheem, that service will be at your cost.
  • Page 5 3. WHAT IS COVERED BY THE RHEEM WARRANTY FOR THE WATER HEATERS DETAILED IN THIS DOCUMENT Rheem will repair or replace a faulty component of your water heater if it fails to operate in accordance with its specifications as follows:...
  • Page 6 The Rheem warranty (set out above) is in addition to any rights and remedies that you may have under the Australian Consumer Law.
  • Page 7: Safety, Warnings, Installation Notes

    • Temperature controllers must not be fitted to this water heater (872 series) if it is installed as an in-series gas booster with a solar water heater system because water at a temperature much higher than the controller setting can be delivered.
  • Page 8 Alternatively the water heater can be installed recessed into a wall, using a proprietary made recess box from Rheem for such an installation. Refer to the installation instructions which accompany the recess box kit for “Recess Installation” the dimensions of the space required and information on its installation. Refer also to...
  • Page 9: About Your Water Heater

    GAS BOOSTING FOR A SOLAR WATER HEATER The 872 series water heater may be installed as an in-series gas booster to a solar water heater. Water stored in the solar storage tank passes through the in-series gas booster when a hot tap is opened. The in-series gas booster is for heating water at times of low solar energy gain, such as during cloudy or rainy weather, or during colder months.
  • Page 10 HOTTER WATER INCREASES THE RISK OF SCALD INJURY An 872 series water heater can deliver hot water at a temperature up to 82°C depending upon its preset outlet temperature setting. This temperature is sufficiently hot to cause severe scalding. Water at this temperature may have been plumbed to fixtures where water hotter than 50°C is allowed, such as a kitchen, laundry and...
  • Page 11 The frost protection system will be rendered inoperable if electrical power is not available at the water heater. Damage caused by freezing due to the unavailability of power at the water heater is not covered “Terms of the Rheem Warranty” by the Rheem warranty (refer to on page 4). •...
  • Page 12 Service or their nearest Accredited Service Agent / Centre. Note: The service and routine replacement of any components, if required, are not included in the Rheem warranty. A charge will be made for this work. Only genuine replacement parts should be used on this water heater.
  • Page 13 Note: It is recommended not to screw the drain plugs back in, until the water heater is to be turned on again. CIRCULATED HOT WATER FLOW AND RETURN SYSTEM A Rheem 872627 model continuous flow water heater can be installed as part of a circulated hot water flow “Circulated Hot Water Flow and Return System”...
  • Page 14: Water Supplies

    In a corrosive water supply, the water can attack copper parts and cause them to fail. Where the saturation index is less than –1.0, the water is very corrosive and the Rheem warranty does not apply to a copper heat exchanger in a continuous flow water heater.
  • Page 15: Save A Service Call

    Check the items below before making a service call. You will be charged for attending to any condition or fault, °C “Terms of the Rheem Warranty” which is not related to manufacture or failure of a part (refer to on page 4).
  • Page 16 • Collector area is too small For most installations, the number of solar collectors recommended in Rheem literature has been proven to provide the required solar energy to meet the average family needs. However, in some circumstances, it may be necessary to install an additional solar collector.
  • Page 17 If the error code persists, take note of the numerical code, turn off the hot tap and turn off the controller(s). Phone Rheem Service or their nearest Accredited Service Agent / Centre to arrange for inspection.
  • Page 18: Installation - Water Heater

    The 872 series of water heater may be installed as an in-series gas booster to a solar water heater. For information relating to the function and operation of the solar water heater, refer to the Owner’s Guide and Installation Instructions supplied with the solar water heater.
  • Page 19 Note: Two or more of this model water heater can be installed side by side with minimal clearance between them. Rheem 872627 models are certified for installation with an exemption from the 300 mm minimum clearance requirements between flue terminals, as stated in AS/NZS 5601.1 clause 6.9.3.
  • Page 20 PIPE COVER The pipe work to the water heater can be housed within a pipe cover. A pipe cover kit (Rheem AU – Part 299425, NZ – Part 320116) is available for such an installation. Refer to the installation instructions which accompany the pipe cover kit.
  • Page 21 Damage to the water heater caused by freezing of the pipe work to or from the water heater is not covered under the Rheem warranty. Refer to AS/NZS 3500.4 for precautions to be taken for installations in frost prone areas. The water heater is not suitable for installation in areas where the ambient temperature falls below - 20°C (including wind chill factor).
  • Page 22 INSTALLATION – WATER HEATER HOT WATER DELIVERY An 872 series water heater can deliver hot water at a temperature up to 82°C depending upon its preset outlet temperature setting. This temperature is sufficiently hot to cause severe scalding. Water at this temperature may be plumbed to fixtures where water hotter than 50°C is allowed, such as a kitchen, laundry and other...
  • Page 23 INSTALLATION – WATER HEATER Warning: A non-return valve MUST BE installed on the cold water line to the solar storage tank AFTER the cold water branch to a temperature limiting device prior to an open circuit system. If a combination isolation valve and non-return valve (duo or trio valve) is installed on the cold water line to an open circuit solar water heater and the cold water line to the temperature limiting device branches off after this valve, then a second non-return valve must be installed between the cold water branch and the solar storage tank.
  • Page 24 INSTALLATION – WATER HEATER CIRCULATED HOT WATER FLOW AND RETURN SYSTEM A Rheem 872627 model continuous flow water heater can be installed as part of a circulated hot water flow and return system in a building. Notes • the preset outlet temperature setting of the water heater must be set to at least 60°C – AU or 65°C – NZ.
  • Page 25 INSTALLATION – WATER HEATER Circulated Hot Water Flow and Return - Continuous Flow Gas Water Heater from solar storage tank Circulated Hot Water Flow and Return In-series Gas Booster as part of a Solar Water Heater Installation...
  • Page 26 INSTALLATION – WATER HEATER DIMENSIONS AND TECHNICAL DATA 872627 872627 Models Natural Universal Propane LP Gas Water heating capacity litres / min 16.7 16.0 @ 40°C rise Nominal capacity litres / min @ 25°C rise Mass Empty (unpackaged) Technical data is subject to change Gas Details Hourly Gas Test Point Gas Pressure (kPa)
  • Page 27 INSTALLATION – WATER HEATER TYPICAL INSTALLATION – OUTDOOR LOCATION...
  • Page 28: Connections - Plumbing

    This damage to components or blockage of filters is not covered by the Rheem warranty and a service rectification fee will be charged. A full flow gate valve or ball valve must be installed on the cold water line or solar preheat water line to the water heater.
  • Page 29 Warning: Always isolate the water heater before pressure testing the gas supply system. Disconnect the water heater after the isolation valve to prevent the risk of serious damage to the gas control. The Rheem warranty does not cover damage of any nature resulting from failure to observe this precaution. Refer to rating...
  • Page 30: Connections - Electrical

    Wiring Rules AS/NZS 3000 and all local codes and regulatory authority requirements. Warning: Temperature controllers must not be fitted to this water heater (872 series) if it is installed as an in-series gas booster with a solar water heater system because water at a temperature much higher than the controller setting can be delivered.
  • Page 31: Multiple Installations

    Sufficient space must be left to enable access, servicing or removal of any water heater. The water heaters can be installed side by side with minimal clearance between them. Rheem 872627 models are certified for installation with an exemption from the 300 mm minimum clearance requirements between flue terminals, as stated in AS/NZS 5601.1 clause 6.9.3.
  • Page 32 MULTIPLE INSTALLATIONS Refer to the diagram on page 32 for installation and plant layout details. PRESSURE REDUCING VALVE COMMISSIONING PROCEDURE The pressure reducing valves must be set and commissioned for each water heater so the water heaters will turn on and off in sequence when the flow rate increases or decreases to a particular rate. This procedure can be conducted with either cold water or solar preheated water, however the temperature of the solar preheated water must be at least 2°C lower than the preset outlet temperature setting of the water heater.
  • Page 33 MULTIPLE INSTALLATIONS To set and commission the pressure reducing valves: Commissioning: Commission each of the water heaters prior to setting the pressure reducing valve on “Commissioning” the cold (or solar preheat) branch to the water heater (refer to on page 34). Turn on services: Turn on the water, gas and electricity to the water heaters.
  • Page 34: Commissioning

    COMMISSIONING All water heaters are tested and adjusted before dispatch from the factory, however further adjustments may become necessary because of local conditions. Note: If this water heater is installed as part of a multiple installation, i.e. in a bank of water heaters, it will be necessary to isolate the other water heaters and commission the water heaters one at a time.
  • Page 35 COMMISSIONING Gas Inlet Test Point Pressure To check the gas inlet pressure: Close any hot taps and ensure the burners are not operating. Close the gas isolation valve at the gas inlet to the water heater. Locate the gas inlet test point on the gas connection to the water heater.
  • Page 36 Note: If an 872 series model is installed as an in-series gas booster for a solar water heater, then the temperature of the water entering the in-series gas booster must be at least 2°C below the water heater preset outlet temperature setting.
  • Page 37 COMMISSIONING Notes • If the burners extinguish and error code 11 or 12 starts to flash on the LED display: release the MIN and adjuster buttons ◼ close the hot tap ◼ “Clearing Error Code” clear the error code (refer to on page 37) ◼...
  • Page 38 COMMISSIONING PRESET OUTLET TEMPERATURE SETTING The factory preset outlet temperature setting of the water heater is: • 60°C – AU 872 series for a single water heater 55°C – NZ for a single water heater 60°C as part of a Multipak system 70°C...
  • Page 39 The increments are 38°C, 40°C, 42°C, 43°C, 45°C, 50°C, 55°C, 60°C, 65°C, 70°C, 75°C, 82°C. Set the LED display to 82 on an 872 series water heater if it is required to deliver sanitising temperatures. Switch dip switches 3 and 4 to the off (down) position.
  • Page 40: Draining The Water Heater

    The frost protection system will be rendered inoperable if electrical power is not available at the water heater. • Damage caused by freezing due to the unavailability of power at the water heater is not covered by the “Terms of the Rheem Warranty” Rheem warranty (refer to on page 4). •...
  • Page 41 This page is intentionally blank.
  • Page 42 This page is intentionally blank.
  • Page 43 This page is intentionally blank.
  • Page 44 Revision Date: 2020 November (41-16795-00) 122471H...