Finishing

A. Mantel Projections
Figure 10.1 shows the minimum vertical and corresponding
maximum horizontal dimensions of appliance mantels or
other combustible projections above the top front edge
of the appliance, not the surround.
for required clearances when using Halston or Galleria
Doors.
Note: When using Galleria or Halston Doors with
FB-GRAND-S and FB-IN-S, a 15 inch minimum
vertical distance from top of door to bottom of
mantel is required.
INLET AIR
EXHAUST
VENT PIPE
VENT PIPE
Figure 10.1 Clearances to Mantels or other Combustibles
above Appliance
12 IN. MAX.
Figure 10.2 Clearances to Mantels or other Combustibles above
Appliance when using Galleria or Halston Doors
20
See Figure 10.2
12 in. MAX.
MANTEL
12 in. MIN.
MEASUREMENTS FROM
TOP EDGE OF UNIT
MANTEL
15 IN. MIN.
TOP OF DOOR
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08
B. Installing Trim Surrounds
Combustible materials MUST NEVER overlap onto the
front face.
1. Find the coiled low voltage wires and ON/OFF switch at-
tached to outer right side of the insert (see Figure 10.2).
2. Reconnect the low voltage wires to the ON/OFF
switch.
3. Attach surround assembly by hooking the support
bracket on the locating tabs on top of the gas insert
fi replace (see Figure 10.2.) Once the surround assem-
bly is on the locating tabs, ensure the bottom hooks
are resting on the locating pins at the base. Reposition
the fi replace if necessary. Refer to surround instruc-
tions provided with the decorative surround.
LOCATING TABS
LOCATING SLOTS
Figure 10.3 Trim Surround Installation
FIREBOX