Heat & Glo FB-GRAND-S Owner's Manual page 19

Hearth and home gas inserts owner's manual installation and operation
Hide thumbs Also See for FB-GRAND-S:
Table of Contents

Advertisement

BLK
BLK
BLK
TEMPERATURE
SENSOR SWITCH
NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED,
IT MUST BE REPLACED WITH TYPE
105
0
C RATED WIRE.
Figure 9.4 Fan Wiring Diagram
VARIABLE SPEED CONTROL
JUNCTION BOX
BLK
BLK
BLK
BLK
110-120 VAC
BEND
UP TABS
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08
BLK
BLK
WHT
WHT
GROUND
GRN
WHT
FAN
GROUND WIRE
(ATTACH TO ANY
METAL SURFACE)
BLOWER RECEPTACLE
BLOWER
JUNCTION
BOX
TEMPERATURE
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)