Vent Information And Diagrams; Vent Table Key; Horizontal Venting; Measuring Standards - Heat & Glo FB-GRAND-S Owner's Manual

Hearth and home gas inserts owner's manual installation and operation
Hide thumbs Also See for FB-GRAND-S:
Table of Contents

Advertisement

5 5

Vent Information and Diagrams

A. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
Symbol
V
Minimum Vertical Run Length 14 ft.
MIN
V
Maximum Vertical Run Length 50 ft.
MAX
B. Horizontal Venting
Horizontal venting is NOT allowed.
C. Measuring Standards
Vertical measurements listed in the vent diagram (Figure
5.1) were made using the following standard:
• Vertical terminations are measured to top of chimney.
Note: To achieve optimum
per formance of insert,
minimize or avoid bends
in exhaust vent pipe.
Figure 5.1
10
Description
EXHAUST COLLAR
INLET AIR COLLAR
V= 14 FT. MINIMUM
50 FT. MAXIMUM
(Factory installed to
stainless steel section)
BLOCK PIPE END WITH
INSULATION OR ANY OTHER
STAINLESS STEEL
REQUIRED (INCLUDED)
COLLAR ATTACHMENT
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a
chimney fl ue serving a separate solid fuel or
gas burning appliance.
• May impair safe operation of this appliance
or other appliances connected to the fl ue.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
ALL vent specifi cations MUST be followed.
• This product is tested and listed to these specifi cations.
• Appliance performance will suffer if specifi cations are not
followed.
TERMINATION
CAP
ADAPTOR
EXHAUST
VENT PIPE
3 INCH COLLAR
WARNING: DO NOT
SEALING MATERIAL
PIPE - 3 FT. MIN.
INLET AIR
VENT PIPE
BRACKET
WARNING
CAUTION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fb-in-s

Table of Contents