Maintenance And Service; Maintenance Tasks-Homeowner - Heatilator B-Vent Gas Appliance CB4236MIR Owner's Manual

B-vent gas appliance
Table of Contents

Advertisement

3 3

Maintenance and Service

Any safety screen or guard removed for servicing must be
replaced prior to operating the fi replace.
When properly maintained, your fi replace will give you
many years of trouble-free service. We recommend an-
nual service by a qualifi ed service technician.
A. Maintenance Tasks-Homeowner
Installation and repair should be done by a qualifi ed service
technician only. The fi replace should be inspected before use
and at least annually by a professional service person.
The following tasks may be performed annually by the
homeowner. If you are uncomfortable performing any of
the listed tasks, please call your dealer for a service ap-
pointment.
More frequent cleaning may be required due to lint from
carpeting or other factors. Control compartment, burner
and circulating air passageway of the fi replace must be
kept clean.
CAUTION! Risk of Burns! The fi replace should be
turned off and cooled before servicing.
Glass Cleaning
Frequency: Seasonally
By: Homeowner
Tools Needed:
Protective gloves, glass cleaner, drop cloth
and a stable work surface.
CAUTION! Handle fi xed glass assembly with care.
Glass is breakable.
Avoid striking, scratching or slamming glass
Avoid abrasive cleaners
DO NOT clean glass while it is hot
Prepare a work area large enough to accommodate fi xed
glass assembly and door frame by placing a drop cloth
on a fl at, stable surface.
Note: Fixed glass assembly and gasketing may have residue that
can stain carpeting or fl oor surfaces.
Remove door or decorative front from fi replace and set
aside on work surface.
See Section 14.I. for instructions to remove fi xed glass
assembly.
Clean glass with a non-abrasive commercially available
cleaner.
-
Light deposits: Use a soft cloth with soap and
water
-
Heavy deposits: Use commercial fi replace glass
cleaner (consult with your dealer)
Carefully set fi xed glass assembly in place on fi replace.
Hold glass in place with one hand and secure glass
latches with the other hand.
Reinstall door or decorative front.
12
Heatilator • Caliber Mesh BV Series • 4040-848 Rev G • 10/08
Doors, Surrounds, Fronts
Frequency: Annually
By: Homeowner
Tools needed:
Protective gloves, stable work surface
Assess condition of screen and replace as necessary.
Inspect for scratches, dents or other damage and repair
as necessary.
Check that louvers are not blocked.
Vacuum and dust surfaces.
Remote Control
Frequency: Seasonally
By: Homeowner
Tools needed: Replacement batteries and remote control in-
structions.
Locate remote control transmitter and receiver.
Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
Place batteries as needed in remote transmitters and
battery-powered receivers.
Place remote control out of reach of children.
If not using your fi replace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
Remove batteries from remote controls.
Unplug 3 volt adapter plug on IPI models.
Venting
Frequency: Seasonally
By: Homeowner
Tools needed:
Protective gloves and safety glasses.
Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
Verify termination cap clearance to subsequent
construction (building additions, decks, fences, or
sheds). See Section 6.
Inspect for corrosion or separation.
Verify weather stripping, sealing and fl ashing remains
intact.
Inspect draft shield to verify it is not damaged or missing.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cb4842mir

Table of Contents