Heatilator CRAVE4836 Installation Manual
Heatilator CRAVE4836 Installation Manual

Heatilator CRAVE4836 Installation Manual

Installation and appliance setup
Hide thumbs Also See for CRAVE4836:
Table of Contents

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator CRAVE4836

  • Page 1 See Table of Contents for location of additional Commonwealth of Massachusetts requirements. gases, unless a certifi ed kit is used. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 2: Table Of Contents

    B. Securing and Leveling the Appliance ....34 C. Installing Non-Combustible Facing Material ..35  = Contains updated information. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date) = Contains updated information. 2301-972 Rev. D 5/15 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 4: Product Specifi C And Important Safety Information

    B. Glass Specifi cations This appliance is equipped with 5 mm ceramic glass. Re- place glass only with 5 mm ceramic glass. Please contact your dealer for replacement glass. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 5: High Altitude Installations

    • A 110-120 VAC circuit for this product must be pro- tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 6: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 7: Getting Started

    Call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 8: Framing And Clearances

    24-1/2 1575 1575 7-1/4 7-1/4 8-9/16 8-9/16 8-7/8 8-7/8 2-3/4 2-3/4 46-3/16 1173 1473 23-3/4 23-3/4 17-1/8 17-1/8 30-1/2 30-1/2 Figure 3.1 Appliance Dimensions - CRAVE4836,CRAVE6048 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 9 24-1/2 1575 1880 7-1/4 7-1/4 8-9/16 8-9/16 8-7/8 8-7/8 2-3/4 2-3/4 1778 2083 23-3/4 23-3/4 17-1/8 17-1/8 30-1/2 30-1/2 Figure 3.2 Appliance Dimensions - CRAVE7260, CRAVE8472 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 10 1575 1575 7-1/4 7-1/4 8-9/16 8-9/16 8-7/8 8-7/8 2-3/4 2-3/4 46-3/16 1173 1473 23-3/4 23-3/4 17-1/8 17-1/8 30-1/2 30-1/2 Figure 3.3 Appliance Dimensions - CRAVE4836ST, CRAVE6048ST Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 11 24-1/2 1575 1880 7-1/4 7-1/4 8-9/16 8-9/16 8-7/8 8-7/8 2-3/4 2-3/4 1778 2083 23-3/4 23-3/4 17-1/8 17-1/8 30-1/2 30-1/2 Figure 3.4 Appliance Dimensions - CRAVE7260ST, CRAVE8472ST Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 12 The Four Square decorative front has an installed depth of 2-1/8 in. (54 mm), measured from the front of the non-combustible fi nishing material to the front of the decorative front. Figure 3.5 Four Square (Overlap Fit) Decorative Front Dimensions Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 13 The Illusion decorative front has an installed depth of 2-1/2 in. (64 mm), measured from the front of the non-combustible fi nishing material to the front of the decorative front. Figure 3.6 Illusion Decorative Front Dimensions Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 14 37-3/16 49-3/16 1249 61-3/16 1554 73-3/16 1859 40-5/16 1024 52-5/16 1329 64-5/16 1634 76-5/16 1938 Figure 3.7 Clean Face Trim Front (Inside Fit) Decorative Front Dimensions Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 15: Clearances To Combustibles

    18-3/4 10.14 and CRAVE7260 Millimeters 2019 2013 2854 10.15. Inches 84-1/4 124-3/8 35-1/4 18-3/4 CRAVE8472 Millimeters 2235 2140 3159 Figure 3.8 Appliance Locations: CRAVE Single-Sided Models Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 16: Constructing The Appliance Chase

    (or an equivalent method may be used) to achieve maximum air tightness. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 17 ***= If appliance is installed off of fl oor, maintain required clearances to combustibles. Construct platform in accordance with local building codes. Figure 3.10 Clearances to Combustibles-CRAVE4836, CRAVE6048, CRAVE7260, CRAVE8472 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 18 ***= If appliance is installed off of fl oor, maintain required clearances to combustibles. Construct platform in accordance with local building codes. Figure 3.11 Clearances to Combustibles-CRAVE4836ST, CRAVE6048ST, CRAVE7260ST, CRAVE8472ST Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 19: Floor Protection

    fi replace or chimney. • Failure to maintain airspace could cause overheating and fi re. Figure 3.12 Floor Protection Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 20: Termination Location And Vent Information

    Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 4.1 Minimum Height From Roof To Lowest Discharge Opening Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 21: Chimney Diagram

    2 sides beneath the fl oor. • Vinyl siding shield is required for use with vinyl siding. Figure 4.3 Minimum Clearances for Termination See Service Parts list for information. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 22: Approved Pipe

    • Horizontal termination cap should have a 1/4 inch downward slant to allow any moisture in cap to be released. Vertical 8-1/2 in. Horizontal Figure 4.4 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 23 18 ft. 5.5 m 9 ft. 2.7 m 21 ft 6.4 m = 63 ft. (19.2 m) Maximum = 40 ft. (12.2 m) Maximum Figure 4.5 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 24 = 63 ft. (19.2 m) Maximum = 63 ft. (19.2 m) Maximum = 40 ft. (12.2 m) Maximum = 40 ft. (12.2 m) Maximum INSTALLED HORIZONTALLY Figure 4.6 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 25 = 63 ft. (19.2 m) Maximum = 63 ft. (19.2 m) Maximum = 40 ft. (12.2 m) Maximum = 40 ft. (12.2 m) Maximum Figure 4.7 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 26 Note: If installing a vertical vent/termination off the top of the appliance, the optional exhaust restrictor may be needed. Note: Use DVP Series components only. Figure 4.8 Vertical Vent Maximum Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 27 NOTICE: Before painting, contact your dealer for Figure 4.11 Set the Exhaust Restrictor information on the appropriate high temperature paint. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 28 = 63 ft. (19.2 m) Maximum = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum Total = 23 ft. (7.1 m) Maximum Total Figure 4.12 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 29 15 ft. 4.5 m = 23 ft. (7.1 m) Maximum = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum INSTALLED HORIZONTALLY Figure 4.13 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 30: Vent Clearances And Framing

    * Shows center of vent framing hole for top venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 5.2 Wall Penetration Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 31: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 32: Installing The Optional Heat-Zone Gas Kit

    Kit instructions for the ® remaining installation steps. HEAT ZONE ® LOCATION LEFT AND RIGHT SIDES HEAT ZONE ADAPTER BOX ® Figure 5.5 Heat Zone Adapter Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 33: Appliance Preparation

    See Figure 6.2. GASKET GASKET ROPE RING ROPE RING Figure 6.2 Fiberglass Rope Ring Installed Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 34: Securing And Leveling The Appliance

    SHIPPING FLANGE FLANGE FLANGE FLANGE Figure 6.5 Nailing Tabs Figure 6.4 Nailing Tabs Installation Position Shipping Position NAILING TABS BOTH SIDES Figure 6.3 Nailing Tab Locations Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 35: Installing Non-Combustible Facing Material

    • Use a wet or dry towel or soft brush to remove dust or dirt from facing material. • See Section 10 for fi nishing materials guidelines. Figure 6.6 Install Factory-Included Non-Combustible Facing Material Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 36: Venting And Chimneys

    Use screws no longer than 1/2 INCORRECT in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. Figure 7.4 Seams Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 37: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 38: Disassemble Vent Sections

    Figure 7.10 • Pull carefully to separate the pieces of pipe. Figure 7.9 Rotate Seams for Disassembly Figure 7.10 Align and Disassemble Vent Sections Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 39: Vertical Termination Requirements

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 7.12. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 40: Horizontal Termination Requirements

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be fi eld constructed. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 41 1-1/2 IN. (38 MM) MIN. HEAT SHIELD OVERLAP WALL SHIELD FIRESTOP SLIP SECTION CAN BE EXTENDED INNER VENT SHEATHING OUTER VENT INTERIOR EXTERIOR Figure 7.15 Venting Through the Wall Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 42: Electrical Information

    3. Remove screws on left and right sides of component heat shield and lift it out of the control cavity. Figure 8.3. Valve Cavity (Lower Access Panel Removed) Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 43: Wiring Requirements

    CORD ADAPTER BLACK BROWN ORANGE GREEN (PILOT) (MAIN) GROUND LED CONTROL BATTERY PACK 6V DC LED LIGHT TRAY Figure 8.4 IntelliFire™ Plus Wiring Diagram with Remote Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 44: Gas Information

    3. Unplug the 6V transformer from the junction box. pressure testing gas line at test pressures equal to or less than 1/2 psig. This will turn the power off to the appliance. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 45 Figure 9.5. Gas Fitting Access with Vanity Panel Removed BURNER ASSEMBLY 4836 & 6048 BURNER ASSEMBLY 7260 & 8472 Figure 9.3. Media Tray with Burner and Pilot Shield Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 46: Gas Connection

    fl ame. Fittings and connections could have loos- ened during shipping and handling. WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 47: Air Shutter Setting

    Full Open CRAVE8472 Propane CRAVE8472ST DETAIL Standard Standard GLASS REFRACTORY Opening= Opening= 1/2 in. Full Open LOG KIT 1/2 in. Full Open Figure 9.6 Air Shutter Location Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 48: Finishing

    Inadequate air space could cause overheating and fi re. To Avoid Sheetrock Cracking: DO NOT Use a quick set or light weight joint compound. Use fl at paint. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 49 If desired fi nishing includes a painted wall, 100% acrylic latex with compatible primer is recommended around this appliance. Oil-based or standard acrylic paints may dis- color due to heat exposure. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 50 Overlap fi t decorative fronts include the Four Square and Illusion. The Clean Face Trim Front (CFT) is an inside fi t decorative front. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 51 FINISHING TEMPLATE BOTTOM ACCESS PANEL = RECTANGULAR ACCESS HOLES DO NOT COVER Figure 10.4 Non-Combustible Finish Material Diagram for 0-1 Inch Thick Overlap Fit Method Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 52 39-1/8 IN.CRAVE4836/CRAVE4836ST 51-1/8 IN.CRAVE6048/CRAVE6048ST 63-1/8 IN.CRAVE7260/CRAVE7260ST 17-1/4 IN. FIREPLACE VIEWING AREA Figure 10.6 Finished Opening Dimensions - Overlap Fit Method Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 53 • Over heating and fi re could occur. TRIM RING INSTALLED Figure 10.7 Non-Combustible Finish Material Diagram for 1-4 Inch Thick Inside Fit Method Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 54 Figure 10.8 Finishing and Facing Materials - Inside Fit 39-1/8 IN.CRAVE4836/CRAVE4836ST 51-1/8 IN.CRAVE6048/CRAVE6048ST 63-1/8 IN.CRAVE7260/CRAVE7260ST 75-1/8 IN.CRAVE8472/CRAVE8472ST 15-3/4 IN. FIREPLACE VIEWING AREA Figure 10.9 Finished Opening Dimensions - Inside Fit Method Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 55: Mantel And Wall Projections

    Figure 10.10 Minimum Vertical and Maximum Horizontal Figure 10.11 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles - CRAVE4836 and Dimensions of Combustibles - CRAVE7260 and CRAVE6048 CRAVE8472 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 56 Measurement from top edge of opening to bottom of appliance = 24-1/2 IN. Figure 10.13 Minimum Vertical and Maximum Horizontal Dimensions of Non-Combustibles - Inside Fit Finishing Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 57: Decorative Front Dimensions For Finishing

    Finishing materials may be a maximum of 4 in. thick. Stop fi nishing material fl ush with opening. Note: See appliance Owner’s Manual for TV mounting guidelines. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 58: Appliance Setup

    Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity. GLASS CLIPS BOTTOM RETAINING LIP Figure 11.1 Fixed Glass Assembly Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 59: Install Media

    Figure 1. Selecting Flat Media for Pilot Cover. 3. The media placement jig must remain in place while media is placed on the media tray and around the pilot bracket. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 60 7. Place the round media set aside in Step 1 over the pilot shield and areas uncovered by removing the media placement jig. See Figure 4. Figure 7. Fogging the Media Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 61: Install Log Set

    Avoid using media pieces larger than two inches in diameter, these can be disruptive to the fl ame patterns. If you fi nd exra large media pieces, discard. Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 62: Reference Materials

    (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 12.1 DVP Vent Components Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 63 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 12.2 DVP Vent Components Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 64 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Cap Shield Figure 12.3 DVP Vent Components Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 65 213 mm 146 to 213 mm 3° 87° 15 in. (381 mm) 10-1/2 in. 267 mm 10-7/8 in. 276 mm DVP-HRC-SS DVP-HRC-ZC-SS Figure 12.4 DVP Vent Components Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 66 Adapter 7-3/8 IN. 187 mm 17-7/8 IN. 454 mm 14 IN. 356 mm 12 IN. 305 mm SLP-TB1 Basement Vent Cap Figure 12.5 PVI-SLP Vent Components Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 67 100 FT PV Wire Harness PVI-WH100 separately. Use if the PVLP-SLP is installed in a high traffi c area. PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 12.6 PVLP-SLP Vent Components Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...
  • Page 68: Accessories

    Please contact your Heatilator dealer with any questions or concerns. For the location of your nearest Heatilator dealer, please visit www.heatilator.com. Printed in U.S.A. - Copyright 2015 Heatilator • CRAVE4836/ST, CRAVE6048/ST, CRAVE7260/ST, CRAVE8472/ST Installation Manual • 2301-970 Rev. Q • 9/15...

Table of Contents