Heatilator CD4236IR-C Owner's Manual

Heatilator CD4236IR-C Owner's Manual

Installation and operation
Hide thumbs Also See for CD4236IR-C:
Table of Contents

Advertisement

Models:
CD4236IR-C
CD4842IR-C
CD4236ILR-C
CD4842ILR-C
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator CD4236IR-C

  • Page 1 Technologies suggests NFI certifi ed or factory trained appliance is not convertible for use with other professionals, or technicians supervised by an NFI gases, unless a certifi ed kit is used. certifi ed professional. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 2: Congratulations

    As the owner of a new fi replace, you’ll want to read and Your new Heatilator gas fi replace will give you years of carefully follow all of the instructions contained in this durable use and trouble-free enjoyment. Welcome to the owner’s manual.
  • Page 3: Table Of Contents

    E. Junction Box Installation......52 F. Wall Switch Installation for Fan (Optional) ... . 52 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 4 D. Contact Information ......73  = Contains updated information. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 5: Limited Lifetime Warranty

    Limited 3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 9: User Guide

    • Install a switch lock or a wall/remote control with child protection lockout feature. • Keep remote controls out of reach of children. • Never leave children alone near a hot fi replace, whether operating or cooling down. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 10: Fan Kit (Optional)

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 11: Control Module Operation

    WARNING! Risk of Fire or Asphyxiation! DO NOT op- erate fi replace with fi xed glass assembly removed. NG/LP SETTING WIRE LEAD FROM REGULATOR CONNECTS HERE Figure 2.3 Control Module Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 12: Lighting Instructions (Ipi)

    See installation and operating instructions accompanying appliance. For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 13: After Fireplace Is Lit

    Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. In a standing pilot system the pilot will always stay on. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 14: Maintenance And Service

    • Inspect draft shield to verify it is not damaged or missing. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 15: Maintenance Tasks-Qualifi Ed Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Figure 3.1 IPI Pilot Flame Patterns Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 16: Logs/Grate And Valve Assembly Removal

    2 EXTRA 2 EXTRA SCREWS TO BE SCREWS TO BE REMOVED FOR REMOVED FOR CD4842IR-C CD4842IR-C Figure 3.7 CD4842IR-C Extra Metal Refractory Screws Figure 3.4 Remove Screws from Log Tabs Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 17 7. Bend down grate tab at the right of burner assembly. Assembly will slide out to the right. See Figure 3.10. Figure 3.10 Grate Tab Figure 3.11 Valve Assembly Removal Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 18: Burner Identifi Cation/Verifi Cation

    fireplace size fireplace style (for CD models only) CD4236IR-C (NG) CD4236IR-C (LP) CNXT4236IH/T-C (NG & LP) CD4842IR-C (NG) CD4842IR-C (LP) CNXT4842IH/T-C (NG & LP) Figure 3.12 Burner identifi cation Examples Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 19: Installer Guide

    FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C) OPTIONAL WALL SWITCH (SECTION 12.C) MANTEL AND MANTEL LEG (SECTION 5.D) SURROUND HEARTH EXTENSION (not required) GAS LINE (SECTION 11) Figure 4.1 Typical System Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 20: Design And Installation Considerations

    Reciprocating saw Manometer Flat blade screwdriver 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) One 1/4 in. female connection (for optional fan). Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 21: Framing And Clearances

    CD4236 Series Mantel Projections 1295 1067 1829 1438 55-7/8 61-1/2 19-3/4 10-1/8 See Section D. CD4842 Series Mantel Projections 1419 1245 2007 1562 Figure 5.1 Appliance Locations - CD Models Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 22: Constructing The Appliance Chase

    CD4842 Series 1019 1245 * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 12 inches for rear venting with one 90º elbow. Figure 5.2 Clearances to Combustibles Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 23: Clearances

    1 in. (25 mm) min. to perpendicular wall 3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall Figure 5.4 Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 24: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 25 Figure 6.3 Minimum Clearances for Termination • Vinyl protection kits are suggested for use with vinyl siding. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 26: Vent Information And Diagrams

    (see Figure 7.1). Effective DVP12 Height/Length DVP24 DVP36 DVP48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 Figure 7.2 DVP Pipe Effective Length Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 27: Vent Diagrams

    Fire Risk. • When using DVP-HRC-SS and DVP-HRC-ZC- SS termination caps on top vented fi replaces, a 6 inch minimum vertical vent section is required before installing fi rst elbow. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 28 457 mm 18 ft. 5.5 m 2 ft. 610 mm 25 ft. 7.6 m = 40 ft. (12.2 m) Maximum = 25 ft. (7.6 m) Maximum INSTALLED HORIZONTALLY Figure 7.5 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 29 3 ft. 914 mm 16 ft * 4.9 m* 3 ft. 914 mm 14 ft.* 4.3 m* = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum Figure 7.6 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 30 2. Break the fl ue restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 7.9). BREAK HERE Figure 7.9 Flue Restrictor Figure 7.7 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 31 4 ft. 1.2 m 20 ft. 6.1 m = 60 ft. (18.3 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 60 ft (15.2 m) Figure 7.12 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 32 2.7 m 4 ft. 1.2 m 18 ft. 5.5 m 18 ft. 5.5 m = 20 ft. (6.1 m) Maximum = 60 ft. (18.3 m) Maximum INSTALLED HORIZONTALLY Figure 7.13 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 33 Rear Vent - Horizontal Termination = 18 in. (457 mm) Maximum No Elbow Figure 7.14 = 12 in. (305 mm) Maximum CD4236IR One 45º Elbow = 15 in. (381 mm) Maximum CD4842IR Figure 7.15 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 34 1.2 m 12 ft. 3.7 m 15 ft. 4.6 m = 40 ft. (12.2 m) Maximum = 3 ft. (914 mm) Maximum = 20 ft. (6.1 m) Maximum Figure 7.17 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 35 1.8 m 12 ft. 3.7 m 8 ft. 2.4 m 15 ft. 4.6 m = 40 ft. (12.2 m) Maximum = 8 ft. (2.4 m) Maximum INSTALLED HORIZONTALLY Figure 7.19 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 36 = 40 ft. (12.2 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 40 ft. (12.2 m) Maximum = 8 ft. (2.4 m) Maximum INSTALLED Figure 7.21 HORIZONTALLY Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 37: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 38: Install The Ceiling Firestop

    Figure 8.3 Installing Ceiling Firestop INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 39: Installing The Optional Heat-Zone

    • Determine the location for the air register/fan housing assembly. Reference the Heat-Zone ® Gas kit instructions for the remaining installation steps. HEAT-ZONE ® ATTACHES HERE Figure 8.5 Heat-Zone Cover Plate ® Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 40: Appliance Preparation

    Figure 9.5 Remove the insulation from the outer vent pipe. For rear venting there is no insulation in the outer vent pipe. Figure 9.3 Remove the seal cap. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 41: Rear Vent

    (90º) and remove the insulation gasket. Figure 9.10 Discard the vent cap, remove and discard the insulation basket. Figure 9.8 Cut the metal retaining band and fold the sides out. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 42: Installing The Non-Combustible Board

    • Bend out nailing tabs on each side. Figure 9.14 Proper Positioning and Securing of an Appliance • Place the appliance into position. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 43: Installing Vent Pipe (Dvp And Slp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 44: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not Figure 10.5 Adding Venting Components required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 45: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly connection point to appliance. 120º Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 46: Install Decorative Ceiling Components (Slp Only)

    fl aps and the roof. Figure 10.13 WARNING! Risk of Fire! Clean out ALL materials from inside the support box and complete the vertical vent run and termination. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 47: Install Metal Roof Flashing

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 48: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.18. Figure 10.18 Wall Thimble Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 49: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8 in.) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 50: Gas Information

    fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 51: Electrical Information

    IGNITOR SENSE TO JUNCTION BOX (110V) MODULE FLAME MODULATION RC100 RC200 (OPTIONAL WALL CONTROLS) BATTERY PACK 6V DC THERMOSTAT WIRE ASSEMBLY / WALL SWITCH WIRE Figure 12.1 IPI Wiring Diagram Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 52: Electrical Service And Repair

    Figure 12.3 Junction Box Wired to Wall Switch or BC10 leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 53: Finishing

    1 in. (25 mm) min. to perpendicular wall 3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall Figure 13.2 Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 54: Appliance Setup

    Figure 14.2). Care should be taken so that the ports are not covered. Failure to follow this procedure will likely cause lighting and sooting problems. Figure 14.4 Placement of Vermiculite Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 55: Install The Log Assembly

    BASE LOG FRONT FACE FRONT FACE Figure 2. Left Log and Right Log Reference Points Figure 3. Left Log in Proper Position Figure 4. Left and Right Log in Proper Position Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 56: Fixed Glass Assembly

    (when applicable to the paint (TUP-GBK-12) to fog the back panels to match the model). side panels. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 57: Troubleshooting

    D. Pilot valve solenoid. Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 58 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 59: Reference Materials

    Inches Millimeters Location Inches Millimeters 1041 11-11/16 36-1/8 33-1/2 28-1/2 14-1/4 34-5/8 2-1/4 8-1/2 2-7/8 9-11/16 26-7/8 8-1/2 6 dia 39-7/8 1013 40-7/8 1038 Figure 16.1 Appliance Dimensions CD4236IR-C Models Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 60 Location Inches Millimeters Location Inches Millimeters 1219 11-11/16 43-1/8 1096 34-3/8 35-1/2 17-3/4 36-5/8 2-3/8 8-1/2 2-7/8 9-15/16 8-1/2 28-7/8 42-7/8 1089 41-7/8 1064 Figure 16.1 Appliance Dimensions CD4842IR-C Models Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 61: Vent Components Diagrams

    (254 mm) 14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 62 (305 mm) 79 mm 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 16.3 DVP vent components Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 63 Cap Shield 13-7/8 in. 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Figure 16.4 DVP vent components Cap Shield Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 64 (222 mm) 1 in. (25 mm) 7-3/4 to 10-3/8 in. 1-5/8 in. (197 to 264 mm) (41 mm) DVP-FBHT FireBrickTermination Cap DVP-HPC High Performance Cap Figure 16.5 DVP vent components Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 65 SS termination caps on top vented fi replaces, a 6 inch minimum vertical vent section is required before installing fi rst elbow. DVP-HRC-SS DVP-HRC-ZC-SS HORIZONTAL TERMINATION CAP Figure 16.6 DVP vent components Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 66 305 mm 8-11/16 in. 1-1/2 in. 5-1/2 in. 12 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 16.7 SLP Series Vent Components Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 67 724 mm 14-7/16 in. 367 mm 2-5/16 in. 14-7/16 in. 59 mm 13-1/2 in. 367 mm 343 mm SLP-WT-BK SLK-SNKD Wall Thimble-Black Snorkel Termination Cap Figure 16.8 SLP Series Vent Components Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 68 (For use with IPI and DSI appliances only. Must use PVK80-PLUS Kit) 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT FireBrickTermination Cap LDS33/LDS46 Decorative Shroud Catalog # LDS33 LDS46 1219 1829 Figure 16.9 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 69: Service Parts

    Louver Assembly, Top 2208-021 Louver Assembly, Bottom 2208-020 Valve Assembly Refer to valve page Base Pan 2208-100 Junction Box (Plastic) 4021-013 Additional service part numbers appear on following page. 3/14 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 70: Log Set Assembly

    Louver Assembly, Bottom 2210-020 Valve Assembly Refer to valve page Base Pan 2211-100 Junction Box (Plastic) 4021-013 Exhaust Cover Shield 385-105 Additional service part numbers appear on following page. 3/14 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 71 Orifi ce (#51C) - LP 582-851 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 500mA~10A 3/4” long Additional service part numbers appear on following page. Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 72: Service Parts

    CD4236IR-C Conversion Kit LP DCKVP-CAL36 Conversion Kit NG DCKVN-CAL42 CD4842IR-C Conversion Kit LP DCKVP-CAL42 Orifi ce, Pilot NG 593-528 Orifi ce, Pilot LP 593-527 Regulator NG NGK-DXV-50 Regulator LP LPK-DXV-50 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...
  • Page 73: Contact Information

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2014 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. L • 3/14...

This manual is also suitable for:

Cd4842ir-cCd4236ilr-cCd4842ilr-c

Table of Contents