Specifications; Devicenet Communications Specifications; Devicenet General Specifications - Omron E5ARER User Manual

Digital controller devicenet communications
Table of Contents

Advertisement

Specifications

1-2

Specifications

1-2-1

DeviceNet Communications Specifications

Item
Communications protocol
Communica-
Remote I/O
tions functions
communications
I/O allocations
Message com-
munications
Connection format
Baud rate
Communications media
Communications distance
Communications power supply
Maximum number of nodes that
can be connected
Maximum number of slaves that
can be connected
Error control
Power supply
Note
1-2-2

DeviceNet General Specifications

Item
Supply voltage
Allowable voltage range
Current consumption
Vibration resistance
Shock resistance
Dielectric strength
Insulation resistance
Conforms to DeviceNet
• Master-slave connections (polling, bit-strobe, COS, or cyclic)
• Conform to DeviceNet specifications.
• Can allocate any I/O data from the Configurator.
• Can allocate any data, such parameters specific to the DeviceNet and the Digital
Controller variable area.
• Up to 2 blocks for the IN Area, up to a total of 100 words (See note 1.)
• One block for the OUT Area, up to 100 words (The first word is always allocated to
Output Enable Bits.) (See note 2.)
• Explicit message communications
• CompoWay/F communications commands can be sent (commands are sent in
explicit message format).
Combination of multidrop and T-branch connections (for trunk and drop lines)
DeviceNet: 500, 250, or 125 kbps, or automatic detection of master baud rate
Special 5-wire cable (2 signal lines, 2 power lines, and 1 shield line)
Baud rate
Network length
500 kbps
100 m max. (100 m max.) 6 m max.
250 kbps
100 m max. (250 m max.) 6 m max.
125 kbps
100 m max. (500 m max.) 6 m max.
The values in parentheses apply when Thick Cables are used.
11 to 25 VDC
64 (includes Configurator when used)
63
CRC error detection
Power supplied from DeviceNet communications connector
(1) The IN Area can be divided into two blocks only when a CS/CJ-series De-
viceNet Unit is used as the master. (The connection type can also be se-
lected.) If a CVM1, CV, or C200HX/HG/HE DeviceNet Master Unit is used
as the master, the IN Area must be in 1 block with a maximum 100 words
(200 bytes). (Polling connection only.)
(2) If a CVM1, CV, or C200HX/HG/HE DeviceNet Master Unit used, only up
to 32 words can be allocated per node.
DeviceNet power supply: 24 VDC (internal circuit)
DeviceNet power supply: 11 to 25 VDC
DeviceNet power supply: 50 mA max. (24 VDC)
Vibration: 10 to 55 Hz
2
Acceleration: 20 m/s
2
150 m/s
max. 3 times each in 3 axes, 6 directions
2,000 VAC
20 MΩ min. (at 500 VDC)
Specifications
Drop line length
Specifications
Section 1-2
Total drop line length
39 m max.
78 m max.
156 m max.
1-5