Automatic Calibration - Toshiba B-SA4TP SERIES Owner's Manual

Barcode printer
Hide thumbs Also See for B-SA4TP SERIES:
Table of Contents

Advertisement

2. PRINTER SETUP

2.7.4 Automatic Calibration

While "<6>AUTO CALIB" is displayed on the LCD Message Display,
press the [PAUSE] key to enter the Automatic Calibration Mode.
In the Automatic Calibration Mode, whether to activate the automatic
calibration at a power on time or not is selectable. When the automatic
calibration is activated, the printer feeds the media for about 160 mm
each time the power is turned on or the Top Cover is opened, to detect a
print start position.
When "<6>AUTO CALIB" appears, press the [PAUSE] key.
<6>AUTO CALIB
OFF
Use the [FEED] or [RESTART] key to select a desired option.
[RESTART]
[FEED]
After selecting the automatic calibration, press the [PAUSE] key.
1. This function is available only when the media pitch is 10.0 mm to 150.0
mm.
2. When this function is activated, the media length, effective print length,
and sensor type specified in the command are ignored.
3. When the printer cannot find a print start position properly, it will
continue to feed the media for up to 500.0 mm. If that does not work, the
printer will stop, resulting in a paper jam.
4. During an automatic calibration, the printer also feeds the ribbon.
5. An automatic forward feed is not performed immediately after an
automatic calibration, even if the auto forward wait parameter is set to
ON.
E2-35
ENGLISH VERSION EO1-33048
2.7 Setting an Operating Environment
OFF
ON TRANS.
ON REFLECT
NOTES:
Not activated
Activated
(Feed gap sensor)
Activated
(Black mark sensor)