2. PRINTER SETUP
2.7.1 Parameter Setting
(Cont.)
(19) Ribbon Near End Selection
This parameter is to choose the remaining ribbon length where the ribbon
near end is detected.
When "<2>PARAMETER SET" appears, press the [PAUSE] key until
the following display appears.
<2>PARAMETER SET
RBN NEAR END 70m
Use the [FEED] or [RESTART] key to select a desired option.
[RESTART]
[FEED]
After selecting the ribbon near end function, press the [PAUSE] key.
(20) Expansion I/O Interface Type Selection
This parameter is to choose a type of the Expansion I/O interface
operating mode.
This parameter should be set depending on the expansion I/O control
specification of the device to be connected via the expansion I/O
interface. For details, refer to the External Equipment Interface
Specification.
When "<2>PARAMETER SET" appears, press the [PAUSE] key until
the following display appears.
<2>PARAMETER SET
EX.I/O TYPE1
Use the [FEED] or [RESTART] key to select a desired option.
[RESTART]
[FEED]
After selecting an Expansion I/O Interface type, press the [PAUSE] key.
E2-27
ENGLISH VERSION EO1-33048
2.7 Setting an Operating Environment
RBN NEAR END 70m
Near end is detected when the remaining
ribbon is 70m long.
RBN NEAR END 30m
Near end is detected when the remaining
ribbon is 30m long.
RBN NEAR END OFF
Ribbon end is not detected.
EX.I/O TYPE1
EX.I/O TYPE2
TYPE1: Standard mode
TYPE2: Inline mode