Interior Masonry Chimney - Lopi Sheffield Owner's Manual

Freestanding
Table of Contents

Advertisement

Installation
16
Hearth
S t o v e
Direct
Connection
N O T E :
Direct
connections
require installation
of an airtight, non-
combustible
block-off plate or
damper adapter.
Interior or
Exterior
Masonry
Chimney
N O T E :
This type of
installation
requires a UBC
approved
masonry
connector or a
factory built (U.L.
Listed) wall
thimble.
Travis Industries
(for qualified installers only)
NOTE: The chimney must have a clay
tile liner. If it does not, the installation
must use a positive connection (full
reline). The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes (UBC,
etc.). Damage must be repaired prior
to installation. The chimney must be
15' to 33' tall.
Combustible
Mantle
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
NOTE: The chimney must have a
clay tile liner. If it does not, the
installation must use a positive
connection (full reline). The
entire fireplace and chimney must
be clean, undamaged, and meet
all local building codes (UBC,
etc.). Damage must be repaired
prior to installation. The chimney
must be 15' to 33' tall.
See the section "Stove
Placement Requirements" for
minimum clearances required.
Chimney connector sections
See the section
"Floor Protection
Requirements"
Min. 18"
Min. 18"
clearance
to ceiling
93508129
Clay
Liner
Stainless steel
chimney connector
must Extend 1' past
the block-off plate or
to the flue liner
Airtight
Insulated
Clean-Out
Remove damper
or wire it open
Block-off plate or
damper adapter
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
Clay Liner
This type of
installation requires
a UBC approved
masonry connector
or a factory built
(U.L. Listed) wall
thimble.
Make sure the
clean-out seals in
place.
4 020204