Leg Installation; Floor Protection Requirements - Lopi Sheffield Owner's Manual

Freestanding
Table of Contents

Advertisement

Installation
8

Floor Protection Requirements

Stove must be placed on the included legs.
Floor protection must be
non-combustible and at least
.018" thick (26 gauge).
NOTE :
In corner installations with reduced-clearance connector, the clearance to the wall is less
than 6". In this case, floor protection must extend to the wall.
Leveling Bolts
Travis Industries
Min. 6"
Min. 16"
Minimum
38-3/4"
Make sure these rubber tipped
bolts on each leg contact the floor
(they dampen any noise that may
transmit through the hearth). Do
not adjust with weight on the legs,
the rubber tips may tear.
(for qualified installers only)
Min. 6"
93508129
Min. 6"
Minimum 37-7/8"
4 040915