Hearth Stove Direct
Connection
NOTE:
This type of installation is
not allowed in Canada.
NOTE:
Direct connections require
installation of an airtight,
non-combustible block-off
plate or damper adapter.
Interior or Exterior
Masonry Chimney
NOTE:
This type of installation is
not allowed in Canada.
NOTE:
This type of installation
requires a UBC approved
masonry connector or a
factory built (U.L. Listed)
wall thimble.
© Travis Industries
Stove Installation
NOTE: The chimney must have a clay
tile liner. If it does not, the installation
must use a positive connection (full
reline). The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes (UBC,
etc.). Damage must be repaired prior
to installation. The chimney must be
15' to 33' tall.
Combustible Mantle
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
NOTE: The chimney must have a
clay tile liner. If it does not, the
installation must use a positive
connection (full reline). The
entire fireplace and chimney must
be clean, undamaged, and meet
all local building codes (UBC,
etc.). Damage must be repaired
prior to installation. The chimney
must be 15' to 33' tall.
See the section "Stove
Placement Requirements" for
minimum clearances required.
Chimney connector sections
See the section
"Floor Protection
Requirements"
(for qualified installers only)
Max. 8"
Min. 18"
Min. 18"
clearance
to ceiling
100-01161
17
Clay
Liner
Stainless steel
chimney connector
must Extend 1' past
the block-off plate or
to the flue liner
Airtight
Insulated
Clean-Out
Remove damper
or wire it open
Block-off plate or
damper adapter
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
Figure 14
Clay Liner
This type of
installation requires
a UBC approved
masonry connector
or a factory built
(U.L. Listed) wall
thimble.
Make sure the
clean-out seals in
place.
Figure 15
4040909