Installation
Mobile Home Requirements
•
Outside air must be installed - see "Outside Air Requirements" on page 11
•
Chimney connector and chimney must be one of the following types:
• DURAVENT model DVL with DURATEC chimney
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DL with SECURITY model ASHT or S2100 chimney
• METAL-FAB model DW with TG chimney
NOTE: Reduced clearance connectors may not connect to the flue collar – order an appliance
adapter for the connector being used.
•
Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)
Minimum Clearance
(See the illustration below)
A
Sidewall to stove
B
Backwall to stove
C
Cornerwall to stove
D
Connector to sidewall
E
Connector to backwall
F
Connector to cornerwall
a
•
If using offsets, use the connector clearance listed to the
right, not the connector manufacturer's
clearance.
•
The appliance must be secured to the floor (consult your
building official). Secure the outside air boot to the floor
and stove to insure the stove does not dislocate.
•
Mobile home installations require a spark arrester at the
chimney termination.
•
The appliance must be grounded to the chassis of the
mobile home (consult your building official).
WARNING:
DO NOT INSTALL IN SLEEPING ROOM.
CAUTION:
THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
Travis Industries
(for qualified installers only)
Straight Installations
d
e
b
NOTE:
Measure stove clearances to the stove top.
93508129
• GSW Double Wall Chimney Connector with Super Chimney Twenty-One
• SELKIRK METALBESTOS model DS connector with model SSII chimney
• I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
• Standard Masonry Chimney with any one of the above listed connectors
Reduced Clearance
Connector
10"
10-1/2"
3"
20"
9"
10-1/4"
Corner Installations
13
f
c
12" Min.
Connector Clearance
(as outlined above)
Stove Clearance
(as outlined above)
4 020204