Hearth Stove
Installation
NOTE:
This type of installation
requires a full reline
(positive connection).
Interior or Exterior
Masonry Chimney
NOT ALLOWED IN
CANADA UNLESS FULL
RELINE IS USED>.
NOTE:
This type of installation
requires a UBC approved
masonry connector or other
method approved by the
NFPA 211 Standard. See
page 10 for further details.
WARNING:
We strongly recommend a
full reline (positive
connection) when venting
through a masonry chimney.
The Cape Cod is equipped
with a post combustor and
may draft poorly without a full
reline. We also recommend
that a minimum 3' chimney
be added to the minimum
system height for every 1' of
horizontal run.
Always use 45 degree
elbows if possible.
© Travis Industries
Stove Installation
NOTE: The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes
(UBC, etc.). Damage must be
repaired prior to installation. The
chimney must be 15' to 33' tall.
Combustible
Mantle
Floor Protection
(See the section
"Floor Protection
Requirements"
for more details)
NOTE: The chimney must
have a clay tile liner. If it does
not, the installation must use a
full reline (positive
connection). The entire
fireplace and chimney must
be clean, undamaged, and
meet all local building codes
(UBC, etc.). Damage must be
repaired prior to installation.
The chimney must be 15' to
33' tall.
See the section "Stove
Placement Requirements" for
minimum clearances required.
Chimney connector sections
See the section
"Floor Protection
Requirements"
(for qualified installers only)
Min. 36"
Min. 18"
clearance
to ceiling
100-01383
Cap and flashing
prevents water from
entering
The liner must be
stainless steel connector
or flexible vent. Follow
the liner manufacturer's
instructions for installation
and support.
Airtight Insulated
Clean-Out
Remove damper
or wire it open
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
Full Reline
Clay Liner
This type of
installation requires
a UBC approved
masonry connector
or other method
approved by the
NFPA 211 standard.
Make sure the
clean-out seals in
place.
4140402