14
Interior or Exterior
Masonry Chimney
NOTE:
This type of installation is
not allowed in Canada.
NOTE:
This type of installation
requires a UBC approved
masonry connector, an
NFPA 211 approved
method, or a method
approved by local
jurisdictions.
© Travis Industries
Stove Installation
NOTE: The chimney must have a
clay tile liner. If it does not, the
installation must use a positive
connection (full reline). The entire
fireplace and chimney must be
clean, undamaged, and meet all
local building codes (UBC, etc.).
Damage must be repaired prior to
installation. The chimney must be
15' (4.57M) to 33' (10.05M) tall.
Chimney connector sections
Floor
Protection
(for qualified installers only)
Must maintain
min.connector
clearance to
combustibles
STOVE
Must Maintain Stove
and Connector
100-01274
Make sure the
clean-out seals in
place.
Clearances
Clay Liner
This type of
installation requires
a UBC approved
masonry connector
or a factory built
(U.L. Listed) wall
thimble.
Figure 11
4111121