Standard Ceiling With A Factory Built Chimney; Cathedral Ceiling With A Factory Built Chimney - Lopi Liberty Owner's Manual

Hide thumbs Also See for Liberty:
Table of Contents

Advertisement

12
Standard Ceiling
with a Factory
Built Chimney
Cathedral Ceiling
with a Factory
Built Chimney
© Travis Industries
Stove Installation
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Chimney Sections
Insulation
Follow the chimney
manufacturer's instructions
and clearances for floor
penetrations. A ceiling
support is required, an attic
insulation shield is required
where insulation is present.
Chimney Connector Sections
Floor
Protection
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Chimney Sections
Minimum Air Space to
Combustibles (See Chimney
Manufacturer's Instructions)
Chimney Connector
Floor
Protection
(for qualified installers only)
}
}
STOVE
STOVE
100-01274
Follow the chimney
manufacturer's instructions
and clearances for roof
penetrations. A storm collar
and flashing are required
(some require a radiation
shield).
Minimum Air Space to
Combustibles (See
Chimney Manufacturer's
Instructions)
Must Maintain Stove
and Connector
Clearances
Follow the chimney
manufacturer's instructions
}
and clearances for roof
penetrations. A storm
collar, flashing, and
cathedral-style chimney
support are required
(some require a radiation
shield).
Must Maintain Stove
and Connector
Clearances
Minimum 15'
(4.57M)
Maximum 33'
(10.05M)
Figure 7
Minimum 15'
(4.57M)
Maximum 33'
(10.05M)
Figure 8
4111121