NOTE: The chimney must have a
clay tile liner. If it does not, the
installation must use a positive
connection (full reline). The
entire fireplace and chimney must
be clean, undamaged, and meet
all local building codes (UBC,
etc.). Damage must be repaired
prior to installation. The chimney
must be 15' to 33' tall.
See the section "Stove
Placement Requirements" for
minimum clearances required.
Chimney connector sections
See the section
"Floor Protection
Requirements"
Min. 18"
clearance
to ceiling
Clay Liner
This type of
installation requires
a UBC approved
masonry connector
or other method
approved by the
NFPA 211 standard.
Full Re-Line
(recommended)
Make sure the
clean-out seals in
place.