Applications; Unit Location - Nordyne M1B Installation Instructions Manual

Downflow, direct vent (sealed combustion) forced air gas & oil furnaces
Table of Contents

Advertisement

6"
Top Clearance
0" Side
Clearance
to Furnace
Cabinet
Removable
access
panel should
be
installed
above
furnace
door frame
to access
roof jack
-
-_.,,
Nearest
i, Wall or
Partition
Figure 1. Alcove installation
6"
Top Clearance
Provide
min. 235
in. (1516 cm 2)
open free area in
front or side wall
, I
In closet
door
i
located
F
at top,
0" Side
center
Clearar
or bottom
to
CLOSET
DOOR
Figure 2. Closet Installation
------_
Provide
min. 250
6" (152 mm)
sq. in. (1613 cm 2)
Top Clearance
-_._/
((
open free area in
__--_
/i'
front or side wall
/
- !r<_
or
in closet
_
door
_t
a fully
, I
Iouvered
0" Side
door may
Clearance
be used
to Furnace
Cabinet
:iOSET
DOOR
Figure 3. Special
1" Clearance
Part
No.
903773
903413
903890
Blower / Motor
Assembly
Blower
Motor
Wheel
(Hp)
10x 8
1/4
11 x8
1/2
11 x 8
3/4
NC Capacity
(Tons)
2, 21/2& 3
2, 21/2,3 & 4
2, 21/2, 3, 4&._5
Table 2. Blower
Assemblies
Applications
M1 Series gas and M5 Series oil furnaces are
listed direct vent (sealed combustion),
downflow
heating appliances
for manufactured
(mobile)
homes,
recreational
vehicles,
and for use in
residentia!/modular/commercial
construction.
The furnace must be located so that venting can
be properly achieved.
Air conditioning
may be added to structures with
M1/M5 series furnaces using air conditioning
or
conventional
units. This Installation
Instruction
manual
includes
special
requirements
for
incorporation of air conditioning equipment to the
M 1/M5 se rJesof fu maces. See Tabel 12 (page 32).
Multi-speed
blower assemblies
shown in Table
2, have been certified for field installation in M1/
M5 Series furnaces.
Unit Location
, The furnace shall be appropriately
located to
the supply and return air distribution
system
(See Page 7). Sides and back of the furnace
may be enclosed by wall framing. See Minimum
Clearances
(page 2) and Figures 1- 3.
, The furnace
installation
is only intended for
free air return through the furnace door louvers.
DO NOT connect a ducted return air system
directly to the furnace. Improper
installation
may create a hazard and damage equipment,
as well as void all warranties.
, Furnace
may be installed
on combustible
flooring
when
using
NORDYNE
Duct
Connectors.
See pages 9 & 10.
, When installed in a residential
garage,
the
furnace must be positioned so the burners and
the source of the ignition are located no less
than 18 inches above the floor and protected
from physical damage by vehicles.
..........
l¸-
"A"- s6'i
"A" Model
_
w/o Coil
Cabinet
"B'= 76"
"B" Model
j _a
w/Coil
Cabinet
Figure 4. Overall
Dimensions