Electrical Information; Line Voltage Wiring - Nordyne M1B Installation Instructions Manual

Downflow, direct vent (sealed combustion) forced air gas & oil furnaces
Table of Contents

Advertisement

tags supplied must be
ELECTRICAL INFORMATION
4.The four warning
installed asfollows:
o
To weather cap
. Tofuel line connection point (Gas) orfurnace
burner (Oil)
To furnace flame observation
door (Gas or
oil)
. To furnace wall thermostat
5. Transit-mode weather cap to be removed and
upper Roof Jack crown installed (See Figure
24). Do Not Discard screws.
6. Place upper Roof Jack (crown) on to the flue
pipe assembly. NOTE: Make sure inside flue
pipe attaches over inner flue pipe and outer
Roof Jack pipe fits over outer pipe.
7. Secure in place using three (3), #10, 1/2" sheet
metal screws removed in step 5. Do not use
the same holes which secured the rain cap in
place.
8. Remove and discard venting system warning
tags.
WARNING:
Failure to properly secure the flue
pipe to the furnace
may result
in
fire,
explosion
or asphyxiation
when operating
the furnace.
f
UPPER
ROOF
JACK
(CROWN)
WEATHER CAP
FLASHING
C;I:I
PIPE
FLUE ASSEMBLY
I2
soREw
E
Figure 23. Roof Jack Crown
WARNING:
To avoid
electric shock, personal
injury, or death, turn off the electric
power
at the
disconnect
or the
main service
panel before making
any electrical
connections.
, Electrical connections
must be in compliance
with all applicable local codes with the current
revision of the National Electric Code (ANSI/
NFPA 7O).
. For Canadian
installations
the
electrical
connections
and grounding shall comply with
the current Canadian
Electrical
Code (CSA
C22.1 and/or local codes).
Line Voltage Wiring
It is recommended
that 115VAC line voltage be
supplied to the furnace from a dedicated branch
circuit
containing
the correct
fuse or circuit
breaker for the furnace. See Table 10 (page 31).
iMPORTANT
NOTE: An electrical
disconnect
must be installed readily accessible
from and
located
within sight of the furnace.
Refer to
the wiring
diagram
inside the control
box
cover or Figures 40- 45 (pages 34- 39) for the
wiring of your particular
unit. Any other wiring
methods
must
be acceptable
to authority
having jurisdiction.
CAUTION'.
Label all wires prior to disconnection
whenservicingcontrols.Wiringerrors
can cause improper and dangerous
operation. Verify proper operation
after servicing.
IMPORTANT
NOTE:
Proper
line
voltage
polarity must be maintained
in order for the
control system to operate
correctly. Verify
the
incoming
neutral
line is connected
to
the white wire and the incoming "hot" line is
connected to the black wire.The furnace will
not operate unless the polarity and ground
are properly connected as shown in Figure 25.
Route all electrical wiring to the left side of the
furnace. For installation of "A" Cabinet furnaces,
allow sufficient slack in the wiring if an optional
cooling coil cabinet is added at a later time. Use
of copper conductors
is recommended.