Safety Information - Nordyne M1B Installation Instructions Manual

Downflow, direct vent (sealed combustion) forced air gas & oil furnaces
Table of Contents

Advertisement

SAFETY
INFORMATION
Safety markings are used frequently throughout
this manual
to designate
a degree
or level
of seriousness
and should
not be ignored.
WARNING
indicates
a potentially
hazardous
situation
that if not avoided,
could
result in
personal
injury or death. CAUTION
indicates
a potentially
hazardous
situation
that if not
avoided, may result in minor or moderate injury
or property damage.
WARNING:
The
safety
information
listed
below must be followed
during the
installation, service,
and operation
of this furnace.
Failure
to follow
safety
recommendations
could
result in possible
damage
to the
equipment,
serious personal
injury
or death.
o Use only with type of gas approved for this
furnace. Refer to the furnace rating plate.
Install
this furnace
in accordance
to the
minimum clearances to combustible materials
listed in Table 1 (page 5).
Provide adequate combustion airtothe furnace
space as specified on page 23.
Combustion
products
must be discharged
outdoors. Connect this furnace to an approved
vent system, as specified on pages 13 - 14.
Never test for gas leaks with an open flame.
Use a commercially
available soap solution to
check all connections
(page 18).
This furnace is designed
to operate with a
maximum external pressure rise of 0.5 inches
of water column. Consult Table 8 (page 38),
and the rating plate for the proper circulating
air flow and temperature
rise.
NOTE: It is important that the duct system be
designed to handle the desired flow rate and
external pressure rise. An improperly designed
duct system can result in nuisance shutdowns,
and comfort or noise issues.
This furnace may not be used for temporary
heating
of buildings
or structures
under
construction.
When supply ducts carry air circulated by the
furnace to areas outside the space containing
the furnace, the return air shall also be handled
by duct(s) sealed to the furnace casing and
terminating
outside the space containing the
furnace. See page 14.
WARNING:
Do not use this appliance
if any
part has been submerged
under
water. Immediately
call a qualified
service
technician
to inspect the
appliance
and to replace any part
of the control system and any gas
control that has been submerged
underwater.
Notice to installer
Installer
is advised
to carefully
follow
all
instructions and warnings in this manual to insure
maximum
performance,
safety, and operating
efficiency
of these
appliances.
Improper
installation
may create hazardous
conditions,
and will void the appliance warranty.
PROPOSITION
65 WARNING"
This product contains chemicals
known to the state of California
to cause cancer, birth defects
or
other
reproductive
harm.
REQUIREMENTS
AND CODES
This furnace must be installed in accordance with
these instructions,
ale applicable
local building
codes and the current revision of the National
Fuel Gas Code (NFPA54/ANSI
Z223.1) or the
Natural
Gas and Propane
Installation
Code,
CAN/CGA B149.1.
CE generateur
d'air chaud
doit 6tre installe
conformement
aux instructions
du fabricant
et aux codes Iocaux. En Fabsence
de code
local,
respecter
la norme
ANSI
Z223.,1,
institule National Fuel Gas Code ou les codes
d'installation
CAN/GCA-B149.
The Commonwealth
of Massachusetts
requires
compliance
with regulation 248 CMR 4.00 and
5.00 for installation of through-the-wall
vented
gas appliances
as follows:
1. For direct-vent
appliances,
mechanical-
vent heating
appliances
or domestic
hot
water equipment,
where the bottom of the
vent terminal
and the air intake is installed
below four feet above grade the following
requirements
must be satisfied: