Furnace Controls & Functions; Furnace On-Off Switch; Limit Control; Gas Valve - Nordyne M1B Installation Instructions Manual

Downflow, direct vent (sealed combustion) forced air gas & oil furnaces
Table of Contents

Advertisement

4.Whencallforheatis satisfied, t hethermostat
contacts openandthegasvalveshutsoffgas
flow.
WARNING:
Should
overheating
occur, or the gas
supply fails to shut off, shut
off the
manual gas valve to the furnace
before
shutting
off the electrical
supply.
/k AVERTISSEMENT:
En case de temperature
excessive,
ou
sail est
impossible
de cooper
i'alimentation
en
gaz,
fermer
le
robinet manuel d'alimentation
en gaz
du g_n_rateur
d'sir
chaud
avant
de
cooper i'alimentation
61ectrique.
FURNACE CONTROLS
& FUNCTIONS
Furnace On-Off Switch
This switch turns electrical power to the furnace
on and off. The switch must be set in the ON
position for the furnace to operate. For M1G
models, in warm weather there is a possibility
of the blower turning on periodically or operating
continuously
due to a heat buildup within the
furnace by a combination
of warm weather and
heat from the pilot. This is normal operation as
long as there is power to the furnace and the
furnace On-Off switch is in the ON position. If
blower operation is not desired, the furnace On-
Off switch may be set in the OFF position to cut
the electrical power to the furnace. See Figure 35.
Limit Control
This furnace is protected by two high temperature
safety limit switches. The auxiliary (upper) limit
switch and the high temperature
(lower) limit
switch are automatic
reset types. If either limit
trips, the burner will shut off. If either limit switch
trips off again soon after resetting, set the furnace
furnace On-Off switch to the OFF position and
call your authorized serviceman.
See Figure 35.
Gas Valve
The gas valves for the gas furnaces are a 100%
shut-off type and will fail safe, if for some reason
the gas is turned off. The valve is a "step-open"
type for M1G models and "slow-open" for M1M
and M1B models which means it opens to a
low-fire position, and after a few seconds, "steps-
open" to high-fire.
Roll Out Switch
(M1G - 056 & 070)
The furnace is protected by a manual reset safety
switch located on the bottom left hand side of
the combustion
pipe.
Oil Burner
Primary
Control
The primary control for oil gun furnaces starts
the burner, monitors a safe operating cycle, and
shuts the burner off at the end of a heating cycle.
The control uses a light sensing transducer
to
determine
if fuel ignition has been successfully
attained. If ignition is not attained by the end of
the safety ignition timing period, the control shuts
the burner off and enters"lock-out." See Figure 35.
Summer
Cooling
- (B, C, & D Series)
Your furnace is A/C ready, equipped with A/C
relay and transformer.
The unit is equipped to
use a 4-wire thermostat.
When using a 5-wire
thermostat,
RC and RH should be jumped (see
instructions
included with thermostat).
Upper
Limit
Switch \
J
Furnace
On-Off
Switch
J
Oil
Pump
_r:::::[ _
Lower
Limit
-*Switch
_ Fan
Control
_Oil
Burner
Control
Figure 35. Furnace Controls - Oil Furnace
25