Nordyne M4RC 92.1% AFUE Upflow User Manual
Nordyne M4RC 92.1% AFUE Upflow User Manual

Nordyne M4RC 92.1% AFUE Upflow User Manual

High efficiency furnaces

Advertisement

Quick Links

Gas Furnaces
USER MANUAL
M4RC 92.1% AFUE Upfl ow
High Effi ciency Furnaces
M4RL 92.1% AFUE Downfl ow
High Effi ciency Furnaces
Congratulations on the purchase on your new
furnace. With our dedication to quality, superior
reliability, and outstanding warranty, we know
you will be pleased with this new appliance. This
furnace has been designed and built to provide
many years of safe and dependable home comfort,
providing it is properly installed and regular
maintenance has been performed. Improper use
or insuffi cient maintenance can shorten the life of
the furnace and result in serious personal injury
or property damage. Please read this manual
thoroughly and familiarize yourself with the
safety, operation and maintenace procedures for
this furnace.
WARNING:
FIRE OR EXPLOSION HAZARD
• Failure to follow safety warnings exactly
could result in serious injury or property
damage.
• Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
• If you cannot reach your gas supplier, call
the fi re department.
Installation and service must be performed
by a qualifi ed installer, service agency or the
gas supplier.
WARNING:
PROPOSITION 65 WARNING: This product
contains chemicals known to the state of
California to cause cancer, birth defects or
other reproductive harm.

Advertisement

Table of Contents
loading

Summary of Contents for Nordyne M4RC 92.1% AFUE Upflow

  • Page 1 Gas Furnaces USER MANUAL Congratulations on the purchase on your new furnace. With our dedication to quality, superior reliability, and outstanding warranty, we know you will be pleased with this new appliance. This furnace has been designed and built to provide many years of safe and dependable home comfort, providing it is properly installed and regular maintenance has been performed.
  • Page 2: Table Of Contents

    Table of Contents Safety Information ........................3 Air for Proper Combustion ....................3 Flammable Vapors .......................3 Gas Supply and Piping ......................3 Venting System ........................4 Combustibles ........................4 Flood Damage ........................4 Shutting Down the Furnace ....................4 Inspection ..........................4 Filters ...........................4 Description of Furnace ......................5 Furnaces Components......................5 Venting System ........................5 Category IV Furnaces ....................5...
  • Page 3: Safety Information

    SAFETY INFORMATION Gas Supply and Piping WARNING: This furnace does not have a pilot. It is equipped with an ignition device which automatically lights the burner. DO The safety information listed throughout this NOT try to light the burner by hand. manual must be followed during the installation, BEFORE OPERATING smell all around the furnace area service, and operation of this furnace.
  • Page 4: Venting System

    SAFETY INFORMATION Venting System WARNING: It is imperative to maintain proper operation of the venting system. Insuffi cient venting could create the production of excessive amounts of Carbon Monoxide - a colorless, odorless gas that is a deadly poison that could result in serious personal injury or death.
  • Page 5: Description Of Furnace

    DESCRIPTION OF FURNACE Venting System Furnace Components This furnace is designed to fulfi ll the requirements of being The furnace components on page 8 will help you locate classifi ed as a Category IV furnace. This classifi cation is the different parts of the furnace. The control you need related to the furnace’s Annual Fuel Utilization Effi...
  • Page 6: Startup And Shutdown

    STARTUP AND SHUTDOWN Starting the Furnace: Shutting Down the Furnace: 1. Make sure the fi lter is clean and in place. Should you ever need to shut down your furnace for service or maintenance, follow these steps: 2. Make sure the vent system is properly installed. 1.
  • Page 7: Burner Operation

    FREQUENCY OF MAINTENANCE MAINTENANCE ITEM BEGINNING OF EACH END OF EACH MONTHLY HEATING SEASON HEATING SEASON Verify furnace area is free of combustible materials. Verify combustion and ventilation air is not restricted. Verify no signs of physical deterioration of the furnace. Verify no obstructions or restrictions in vent or chimney.
  • Page 8: Location Of Furnace Components

    LOCATION OF FURNACE COMPONENTS STATUS FLAME BLOWER DELAY *RC 92.1% Upfl ow Gas Furnace *RL 92.1% Downfl ow Gas Furnace 1. Blower Assembly 6. Gas Manifold 11. Limit Switch 2. Blower Door Switch 7. Gas Valve 12. Pressure Switch 3. Burner Assembly 8.