8.4-inch diagonal color active matrix LCD module incorporating amorphous
silicon TFTs.
171 mm x 128 mm (21,888 sq. mm)
104 mm x 159 mm (16,536 sq. mm) in Full screen mode
(graphical user interface off)
640 pixels horizontally x 480 pixels vertically
Select from 100 hues, 0-100% saturation and 0-100% luminosity.
Previous sweeps are stored in half bright display and most recent sweep in full
bright. This allows easy differentiation of current and historic information.
When two waveforms overlap, a third color distinguishes the overlap area.
On/Off selectable.
On/Off selectable.
Minimum, Variable (100 ms to 40 s), Infinite. Up to 6 levels of grey scale.
On/Off (Grid or Frame).
0 to 100%
Measurement Conditions
512 point record (2 GSa/s)
33 automatic measurements: V
Preshoot, Overshoot, V
, V
upper
Frequency, Positive Width, Negative Width, Duty Cycle, Delta Time, T
FFT Frequency, FFT Magnitude, FFT Delta Frequency, FFT Delta Magnitude, Eye
Height, Eye Width, Jitter, Crossing %, Q-factor, Duty Cycle Distortion.
Over GPIB only: VTime, TVolts.
Selectable 10%, 50%, 90% or 20%, 50%, 80% or Custom (% or absolute voltage).
Standard or Custom (in absolute voltage).
On/Off selectable. Current measurement, mean, and standard deviation
16 Drag and Drop automatic measurement icons.
Activates 4 preselected automatic measurements.
Manual Markers, Track Waveform Data, Track Measurements.
4 function waveforms f1-f4. Select from Add, Subtract, Multiply, Divide, Invert,
Magnify, Vs, Min, Max, Integral, Differentiate, FFT Magnitude.
Chapter 1: General Information
Specifications & characteristics
Real Time sampling mode, minimum
persistence, triggered sweep, no
interpolation, markers off, math off,
connect the dots off, 1 channel
acquisition, 50 ns/div, statistics off.
Waveforms/sec: > 2,100
V
Measurements/sec: > 130
pp
, V
, V
,V
, V
, V
pp
min
max
avg
amptd
, V
, Rise Time, Fall Time, Period,
middle
lower
, V
, V
,
base
top
rms
, T
,
max
min

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xx410654835a54845a54846a

Table of Contents