A
B
G0592 Metal Cutting Bandsaw
Control Panel
C
D
Figure 2. G0592 control panel.
A. Coolant Pump Switch: Turns the coolant
pump ON.
B. EMERGENCY STOP/OFF Button: Interrupts
power to the system and turns the motor
OFF. Twist the button until it pops out to re-
energize the system. Also works as a stan-
dard OFF button.
Note: The bandsaw has an automatic shut-
off (limit switch) that turns the machine OFF
at the completion of the cutting arc.
C. START Button: Turns the motor ON and
activates moving parts.
D. Power Light: When lit, indicates that system
is energized and machine is ready to oper-
ate.
E. Feed Rate Dial: Fine tunes the feed rate by
controlling the hydraulic valve. Range is from
1 being slowest to 9 being fastest.
F.
Feed Control Knob: Turning the knob to the
left lowers the bow at the feed rate you have
set. Turning the knob to the right locks the
bow in position.
F
E
-7-