Safety (Listing) Label - FireplaceXtrordinair 35 Custom Builder Owner's Manual

Direct vent fireplace
Hide thumbs Also See for 35 Custom Builder:
Table of Contents

Advertisement

3 6
The safety (listing) label is on a plate chained to the gas control valve. A copy of the safety label is
shown below.
Model 35 Custom Builder (CB) Fireplace
Vented Gas Direct-Vent Fireplace Heater
Report No. 028-S-35-5
Tested and certified by OMNI-Test Laboratories, Inc. to the combustion performance and construction requirements of ANSI Z21.88/CSA
2.33-1998, applicable sections of UL 307b and CAN/CGA 2.17-M91.
Must be installed in accordance with all local codes, if any; if not, in USA follow ANSI Z223.1-1992 and NFPA 54(88), in Canada CAN/CGA
B-149. Installation in Manufactured or Mobile Homes must conform with: In USA, Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280; In
Canada, CSA Z240.4 and Gas-Equipped Recreational Vehicles and Mobile Housing. This appliance is only for use with the type of gas indicated on the rating plate and
may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. This appliance
is not convertible for use with other gases, unless a certified kit is used. This appliance uses a millivolt-type control system consisting of a gas control valve/regulator, a
standing pilot burner assembly, a thermopile, a piezo ignitor, and the ON/OFF switch. THIS UNIT DOES NOT REQUIRE 110 VOLT POWER TO OPERATE. All exhaust gases
must be vented outside the structure of the living-area. Combustion air is drawn from outside the living-area structure.
The 35 B is designed to operate on natural gas, or propane (LPG). This appliance is factory set for use with Natural Gas. For conversion to Propane (LPG) use
factory supplied kit. See owner's manual for information on making these changes.
WARNINGS:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the information in the owner's and installation
manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
Operation of this appliance when not connected to a properly installed and maintained venting system or tampering with the blocked vent shutoff system can
result in carbon monoxide (CO) poisoning and possible death.
Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service
person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present. The control compartment, the burner
compartment and all circulating air passageways of the appliance must be kept clean and clear at all times.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
This appliance must not be connected to a chimney flue servicing a separate solid fuel burning appliance.
This vented gas fireplace heater is not for use with air filters.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or clothing ignition.
Young children should be carefully supervised at all times when they are in the same room as the appliance.
This appliance is a Vented Gas Fireplace Heater. Not for use with Solid Fuel.
CAUTIONS:
Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.
Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.All safety screen or guard components
removed for servicing, must be replaced prior to operating the appliance.
Clothing or other flammable material should not be placed on or near the appliance.
Risk of electrical shock. Switch the household breaker off or remove fuse before servicing unit.
Use Simpson DURA-VENT direct vent system (Model GS) to vent this appliance to the exterior (direct discharge only without duct connection).
Travis Industries
Safety Label
Edge of Glass Frame to Adjacent Wall . . . . . .
Wood Floor Beneath Fireplace . . . . . . . . . . . .
Back to enclosure (from stand-offs) . . . . . . . .
Top to enclosure . . . . . . . . . . . . . . . . . . . . . . . . (See Owner's Manual)
* See Owner's Manual For Additional Mantel Clearances and Options.
FAN TYPE VENTED CIRCULATOR
Blower Electrical Rating: 115 V., 1.5 Amps, 60 Hz, 150 watts (optional)
Input Rate on "HI" (BTU/Hr)......... 24,000 24,000
Input Rate on "LO" (BTU/Hr) ....... 13,708 14,342
Main Burner Orifice (DMS) ...........
This appliance is equipped for installation in Canada at 0-4500 ft. (0-1370 m); in USA, 0-2000 ft. (0-610 m).
In USA, for altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See the owner's manual for information on making these changes.
Manufacture
Date:
9 3 5 0 8 1 1 6
Minimum Clearances to Combustibles
8-1/2" (216mm)
Hearth Extension in Front . . . . . . . . . . . . . . . . . . . . . . . . . .
0" (0mm)
Hearth Extension to Sides of Faceplate . . . . . . . . . . . . . . .
0" (0mm)
Sides to enclosure (from stand-offs). . . . . . . . . . . . . . . . . .
Floor to 8" Mantel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42" (1065mm)*
Flue Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Owner's Manual
L.P.
N.G.
Minimum Inlet Pressure (inches W.C.)............. 11.5" 5.5"
Maximum Inlet Pressure (inches W.C.)............
#54
#43
Manifold Pressure on "HI" (inches W.C.) ........
2000
Jan.
Apr.
Jul.
Oct.
2001
Feb.
May
Aug.
Nov.
2002
Mar.
Jun.
Sep.
Dec.
0" (0mm)
0" (0mm)
0" (0mm)
L.P. N.G.
13"
7"
11"
3.5"
10850 117th Pl. N.E. Kirkland, WA 98033
0390
0 3 1 0 0 0