Hearth Requirements - FireplaceXtrordinair 35 Custom Builder Owner's Manual

Direct vent fireplace
Hide thumbs Also See for 35 Custom Builder:
Table of Contents

Advertisement

Installation

Hearth Requirements

The fireplace must be placed on a wood or non-combustible sub-floor.
No hearth is required.
N O T E :
Carpeting or other floor covering (e.g. linoleum, wood flooring) must not protrude 3/4" above
the base of the fireplace. The fireplace must be raised to accommodate any flooring thicker
than 3/4".
HINT :
We strongly suggest using a tile or non-combustible hearth in front of the fireplace. This
protects the area in front of the fireplace from heat dis-coloration or off-gassing. Travis
Industries can not be responsible for floor discoloration in front of the fireplace.
HINT :
If using a 36-DV Face, please be aware that a 1-1/8" gap will appear below the face. We
suggest a non-combustible hearth in front of the face to conceal this area.
Maximum 3/4"
Travis Industries
(for qualified installers only)
9 3 5 0 8 1 1 6
Carpeting or other floor covering
(e.g. linoleum, wood flooring) must
not protrude 3/4" above the base of
the fireplace. The fireplace must be
raised to accommodate any flooring
thicker than 3/4".