Technical Data - Stanley Supreme DF User Manual

Table of Contents

Advertisement

This cooker is either Cat I
Check the appliance data badge.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Behind plinth panel, serial number repeater badge below right hand oven opening.
Country of Destination: GB/IE
Gas
Natural Gas
20mbar
Propane
37mbar
Butane
28 - 30mbar
(See appliance data badge for test pressures)
Dimensions
Overall depth including handles
Overall depth excluding handles
Minimum space above hotplate
Connections
Gas
Rp
1
/
at rear right-hand side
2
Ratings
Hotplate
Left hand front wok
Right hand front Rapide
Rear Semi-Rapide
Centre Fish Burner
Gas burner inputs based on Gross Calorific Value
Fan Ovens
Energy efficiency class on a scale of A (more efficient) to G (less efficient)
Energy Consumption based on a standard load
Usable Volume (litres)
Size
Time to cook standard load
Surface area of the grid
Grill
Slow cooking oven
Maximum total electrical load at 230V 8.5 kW (approximate total including oven lights, etc.)

Technical Data

(Nat Gas) or I
(LP Gas).
2H
3+
Electric
220 - 240V 50Hz
Overall height
minimum 915mm
Overall width
1000mm See 'Positioning of Cooker'
660mm
600mm
Space for fixing
See 'Positioning of Cooker'
800mm
Electric
220 - 240V 50Hz
Natural Gas
Input
Injector
Bypass
3.5 kW
130
3.0 kW
116
1.75 kW
097
2.6 kW
108
2.5kW
1.2kW
Propane Gas
Input
96
3.5 kW (250g/h)
54
3.0 kW (214g/h)
39
1.75 kW (125g/h)
70
2.6 kW (186g/h)
40
maximum 940mm
Injector
Bypass
95
57
85
40
65
32
80
47
Forced air convection
2.5 kW
B
1.05 kWh
49
Medium
50 minutes
2
720cm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents