13

Electrical Information

A. Wiring Requirements
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
Wire the appliance junction box to 0-20 VAC. This is
required for use of optional accessories (standing pilot
ignition) or proper operation of the appliance (Intellifire
ignition).
A 0-20 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
Low voltage and 0 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
Determine if the appliance uses an Intellifire ignition sys-
tem or standing pilot ignition system:
Open the control access panel.
A red or black ignitor button (as shown in Figure .)
indicates this appliance is standing pilot ignition.
Red or Black
Button
Figure 13.1 Ignitor Button
B. Standing Pilot Ignition System Wiring
Refer to Figure 13.2, Standing Pilot Wiring Diagram
The standing pilot ignition system wiring does not require
a 0 VAC supply to operate.
A 0 VAC junction box MUST be installed for use with
a fan or remote control. See Figure .5 for junction box
wiring. Keep wire lengths short as possible.
C. Intellifire Ignition System Wiring
Wire the appliance junction box to 0 VAC for proper
operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
Refer to Figure 13.3, Intellifire Pilot Ignition (IPI) Wiring
Diagram.
This appliance is equipped with an Intellifire control valve
which operates on a -volt system.
Plug the -volt AC transformer into the appliance junction
box to supply power to the unit OR install two D cell
batteries (not included) into the battery pack before
use.
NOTICE: Batteries should not be placed in the battery
pack while using the transformer. Remove batteries before
using the transformer, and unplug the transformer before
installing the batteries. Battery polarity must be correct or
module damage will occur.
D. Optional Accessories Requirements
This appliance may be used with a wall switch or a
remote control.
Wiring for optional Hearth & Home Technologies
approved accessories should be done now to avoid
reconstruction. Follow instructions that come with those
accessories.
Heatilator • Eclipse • 4049-229 Rev I • 08/09
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Edv3633iEdv3633il

Table of Contents