Electrical Information; Wiring Requirements; Intellifire Tm Plus Ignition System Wiring; Optional Accessories Requirements - Heatilator CNXT4236IT-D Owner's Manual

Table of Contents

Advertisement

12

Electrical Information

A. Wiring Requirements
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• Wire the appliance junction box to 110-120 VAC. This is
required for use of optional accessories (standing pilot
ignition) or proper operation of the appliance (IntelliFire
Plus ignition).
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
• Low voltage and 110-120 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
TO JUNCTION
BOX (120V)
FLAME
MODULATION
Figure 12.1 IPI Wiring Diagram
54
Heatilator • CNXT4236IT-D, CNXT4842IT-D, CNXT4236IH-D, CNXT4842IH-D • 2360-900 Rev. i • 5/17
TM
IGNITOR
FLAME
SENSE
MODULE
I
ORANGE
S
WHITE
BATTERY PACK
6V DC (AA X 4)
B. IntelliFire
Plus Ignition System Wiring
TM
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire
control valve which operates on a 6 volt system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
C. Optional Accessories Requirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
• Hearth & Home Technologies recommends that Intel-
liFire
Plus wireless controls be used for their features
TM
and functionality with the IntelliFire
tem.
3 PRONG 110VAC
AUX200 MODULE
Plus
TM
Plus ignition sys-
TM
RC300 4.5V DC
(AAA X 3)
TO JUNCTION
BOX 120VAC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cnxt4842it-dCnxt4236ih-dCnxt4842ih-d

Table of Contents