F. Installing Vertical Termination Cap
Attach the vertical termination cap by sliding the inner
collar of the cap into the inner flue of the pipe section
while placing the outer collar of the cap over the outer
flue of the pipe section.
Secure the cap by driving three self-tapping screws
(supplied) through the pilot holes in the outer collar of the
cap into the outer flue of the pipe (see Figure 10.10).
Termination Cap
Brackets/
Bolts
Caulk
Figure 10.10
G. Assemble and Install Storm Collar
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during installa-
tion. Sheet metal edges are sharp.
(1 of three)
Storm
Collar
Screws
Figure 10.11 Assembling the Storm Collar
Figure 10.12 Assembling the Storm Collar Around the Pipe
Heatilator • Eclipse • 4049-229 Rev I • 08/09
Connect both halves of the storm collar with two screws
(see Figure 0.).
Wrap the storm collar around the exposed pipe section
closest to the roof and align brackets. Insert a bolt
(provided) through the brackets and tighten the nut to
complete the storm collar assembly. Make sure the collar
is tight against the pipe section.
Slide the assembled storm collar down the pipe section
until it rests on the roof flashing (see Figure 10.12).
Caulk around the top of the storm collar (see Figure
0.).