E. Vent Diagrams
To replace the first starter elbow with two 45° elbows,
refer to Figure 7.4. All other 90° elbows can be replaced
with two 45° elbows.
General Rules:
SUBTRACT  ft. from the total H measurement for each
90° elbow installed horizontally.
SUBTRACT -/2 ft. from the total H measurement for
each 45° elbow installed horizontally.
A maximum of three 90° elbows (or six 45° elbows)
may be used in any vent configuration. Some elbows
may be installed horizontally. See Figure 7.9.
Elbows may be placed back to back anywhere in the
system as long as the first 90° elbow is a starter elbow
except as shown in Figure 7.4.
When penetrating a combustible wall, a wall shield
firestop must be installed on both sides.
When penetrating a combustible ceiling, a ceiling
firestop must be installed.
Horizontal runs of vent do not require vertical rise;
horizontal runs may be level.