7

Vent Information and Diagrams

A. Approved Pipe
This appliance is approved for use with Hearth & Home
Technologies SLP venting systems. Refer to Section
7.B for vent component information.
DO NOT mix pipe, fittings or joining methods from differ-
ent manufacturers.
The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each
joint within the wall.
WARNING! Risk of Fire or Asphyxiation. This appliance
requires a separate vent. DO NOT vent to a pipe serving a
separate solid fuel burning appliance.
B. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
Symbol
V
First section (closest to appliance) of vertical length
1
V
Second section of vertical length
2
H
First section (closest to appliance) of horizontal length
1
H
Subsequent sections of horizontal length
2
C. Use of Elbows
Diagonal runs have both vertical and horizontal vent as-
pects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect (see
Figure 7.).
Two 45º elbows may be used in place of one 90º elbow.
On 45º runs, one foot of diagonal is equal to 8-1/2 in. (216
mm) horizontal run and 8-/2 in. (26 mm) vertical run. A
length of straight pipe is allowed between two 45º elbows
(see Figure 7.).
D. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards.
Pipe measurements are shown using the effective length
of pipe (see Figure 7.2).
Measurements are made from the appliance outer wrap,
not from the standoffs.
Horizontal terminations are measured to the outside
mounting surface (flange of termination cap) (refer to
Figure 6.2).
Vertical terminations are measured to bottom of
termination cap.
Horizontal pipe installed level with no rise.
24
Description
Heatilator • Eclipse • 4049-229 Rev I • 08/09
Vertical
On 45° runs, 1 ft (.3 m) of diagonal is equal to 8-1/2 in. (216
mm) horizontal run and 8-1/2 in. (216 mm) vertical run.
Figure 7.1
Using Two 45° Elbows
Effective
Height/Length
SLP Pipe
(see chart)
Figure 7.2
Pipe Effective Length
8-1/2 in.
Horizontal
Effective Height/Length
Pipe
mm
inches
SLP4
4
102
SLP6
6
152
SLP12
12
305
SLP24
24
610
SLP36
36
914
SLP48
48
1219
SLP6A
2 - 6
51 - 152
SLP12A
2 - 12
51 - 305