Table 28. Nmi Signal Generation And Event Logging; Table 29. System Status Led State Definitions - Intel S2600CO series User Manual

Server board
Hide thumbs Also See for S2600CO series:
Table of Contents

Advertisement

Intel® Server Board S2600CO Family TPS
Causal Event
Chassis Control command (pulse diagnostic interrupt)
Front panel diagnostic interrupt button pressed
Watchdog Timer pre-timeout expiration with
NMI/diagnostic interrupt action
8.2.1.5
NIC Activity LED Support
The Front Control Panel includes an activity LED indicator for each on-board Network Interface
Controller (NIC). When a network link is detected, the LED will turn on solid. The LED will blink
once network activity occurs at a rate that is consistent with the amount of network activity that
is occurring.
8.2.1.6
Hard Drive Activity LED Support
The drive activity LED on the front panel indicates drive activity from the on-board hard disk
controllers. The server board also provides a header giving access to this LED for add-in
controllers.
8.2.1.7
System Status LED Support
The System Status LED is a bi-color (Green/Amber) indicator that shows the current health of
the server system. The system provides two locations for this feature; one is located on the
Front Control Panel, the other is located on the back edge of the server board, viewable from
the back of the system. Both LEDs are tied together and will show the same state. The System
Status LED states are driven by the on-board platform management sub-system. The following
table provides a description of each supported LED state.
Color
State
Off
System is
not
operating
Green
Solid on
Green
~1 Hz blink
Revision 1.4

Table 28. NMI Signal Generation and Event Logging

Table 29. System Status LED State Definitions

Criticality
Not ready
1.
2.
3.
4.
Ok
Indicates that the System is running (in S0 State) and its status is
'Healthy'. The system is not exhibiting any errors. AC power is
present and BMC has booted and manageability functionality is up
and running.
Degraded -
System degraded:
system is
operating in a
degraded state
although still
functional, or
system is
operating in
a redundant state
but with an
impending failure
warning
Intel order number G42278-004
Signal
Front Panel Diag Interrupt Sensor Event Logging Support
Generation
X
X
X
System is powered off (AC and/or DC).
System is in EuP Lot6 Off Mode.
System is in S5 Soft-Off State.
System is in S4 Hibernate Sleep State.
Redundancy loss, such as power-supply or fan. Applies only if
the associated platform sub-system has redundancy
capabilities.
Fan warning or failure when the number of fully operational fans
is more than minimum number needed to cool the system.
Non-critical threshold crossed – Temperature (including HSBP
temp), voltage, input power to power supply, output current for
main power rail from power supply and Processor Thermal
Control (Therm Ctrl) sensors.
Power supply predictive failure occurred while redundant power
On-board Connector/Header Overview
NMI
X
X
Description
85

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents