Data Center Management Interface (Dcmi); Table 19. Diagnostic Data; Table 20. Additional Diagnostics On Error - Intel S2600CO series User Manual

Server board
Hide thumbs Also See for S2600CO series:
Table of Contents

Advertisement

Platform Management Functional Overview
6.10.15.1
Output Data Format
The diagnostic feature shall output a password-protected compressed HTML file containing
specific BMC and system information. This file is not intended for end-customer usage, this file
is for customer support and engineering only.
6.10.15.2
Output Data Availability
The diagnostic data shall be available on-demand from the embedded web server, KCS, or IPMI
over LAN commands.
6.10.15.3
Output Data Categories
The following tables list the data to be provided in the diagnostic output. For items in Table 19,
this data is collected on detection of CATERR, ERR2, PERR, SERR, and SMI timeout. The data
in Table 20 is accumulated for the three most recent overall errors.
Internal BMC Data
External BMC Data
External BIOS Data
System Data
System Data
6.10.16

Data Center Management Interface (DCMI)

The DCMI Specification is an emerging standard that is targeted to provide a simplified
management interface for Internet Portal Data Center (IPDC) customers. It is expected to
become a requirement for server platforms which are targeted for IPDCs. DCMI is an IPMI-
based standard that builds upon a set of required IPMI standard commands by adding a set of
DCMI-specific IPMI OEM commands. Intel
be implementing the mandatory DCMI features in the BMC firmware (DCMI 1.1 Errata 1
compliance). Please refer to DCMI 1.1 errata 1 spec for details. Only mandatory commands will
76

Table 19. Diagnostic Data.

Category

Table 20. Additional Diagnostics on Error.

Category
Intel order number G42278-004
BMC uptime/load
Process list
Free Memory
Detailed Memory List
Filesystem List/Info
BMC Network Info
BMC Syslog
BMC Configuration Data
Hex SEL listing
Human-readable SEL listing
Human-readable sensor listing
POST codes for the two most recent boots
SMBIOS table for the current boot
256 bytes of PCI config data for each PCI device
First 256 bytes of PCI config data for each PCI
device
PCI error registers
MSR registers
®
S1400/S1600/S2400/S2600 Server Platforms will
Intel® Server Board S2600CO Family TPS
Data
Data
Revision 1.4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents