13
CONTROL COMMAND
D D To send/read memory contents
When sending or reading memory contents, additional
codes must be added to appoint the memory channel
as follows.
➥ Additional code: 0000–1219
• Memory channel code
Code
Bank number
0000–0999
Bank-0–Bank-9
1000–1099
Bank-A (Auto)
1100–1199
Bank-S (Skip)
1200–1219
Bank-P (Scan edge)
• Memory bank code
Code
00–09
10
11
12
D D Codes for memory name, bank name,
opening message and clock 2 name
contents
To send or read the desired memory name settings,
the character codes as follows are used.
• Character's code
Character ASCII code
0–9
30–39
A–Z
41–5A
a–z
61–7A
space
20
• Character's code— Symbols
Character
ASCII code
!
21
$
24
&
26
?
3F
'
27
^
5E
2D
/
2F
,
2C
;
3B
<
3C
(
28
[
5B
{
7B
|
7C
7E
Memory Cnannel
0–999
A00–A99
S00–S99
P0A–P9B
Bank number
Bank-0–Bank-9
Bank-A (Auto)
Bank-S (Slip)
Bank-P (Scan edge)
Description
Numerals
Alphabetical characters
Alphabetical characters
Word space
Character
ASCII code
#
23
%
25
¥
5C
"
22
`
60
+
2B
2A
.
2E
:
3A
=
3D
>
3E
)
29
]
5D
}
7D
_
5F
@
40
D D Offset frequency setting
The following data sequence is used when sending or
reading the offset frequency setting.
q
X
0
X
D D Tone squelch frequency setting
The following data sequence is used when sending or
reading the tone frequency setting.
q*
0
0
*Not necessary when setting a frequency.
D D DTCS squelch code setting
The following data sequence is used when sending or
reading the DTCS code setting.
q
0
X
Not necessary when normal is set.
0=Normal, 1=Reverse
13-10
w
e
X
X
X
0
w
e
X
X
X
X
w
e
0
X
X
X
r
X

Hide quick links: