8
SCANS

■ Auto memory write scan operation

[SQUELCH]
Scan indicator and Auto memory write scan number appear
[AUTO]
[EXIT/SET]
Auto memory write scan operates in the same way as
programmed scan. However, when a signal is re-
ceived, the received frequency is automatically written
into a memory channel in the auto write bank
(A00–A99).
q Push [EXIT/SET] several times to close a multifunc-
tion screen, if necessary.
w Select the desired VFO or memory channel.
e Select the desired operating mode.
• The operating mode can also be changed while scan-
ning.
r Set [SQUELCH] control open or closed.
• See page 8-3 for squelch condition.
t Push [AUTO] to start the auto memory write scan.
• Selected programmed scan start.
• Scan screen appears.
• "
AUTO MEMORY WRITE SCAN
blink while scanning.
• Push numeral key (0–9) to change to the other edges.
y When the scan detects a signal, the scan stops,
pauses or ignores it depending on the resume set-
ting and the squelch condition.
• The received frequency is automatically written into a
blank memory channel in the auto write bank.
u To cancel the scan, push [AUTO].
• Pushing [F5•STOP] also cancels the scan.
• Pushing [EXIT/SET] closes the scan screen.
i Push and hold [F-6•RECALL] for 1 sec. to recall the
frequency that was set before starting the scan, if
desired.
✔ For your convenience
Ten auto memory write scans can be selected directly
from the keypad. Then the scan starts immediately.
➥ Push numeral key (0–9) then push [AUTO] to start
the desired programmed scan.
The memory clear setting of the auto write bank can
be selected from the starting auto memory write
scan, by pushing and holding [AUTO], or manually.
See scan set mode (p. 8-4) for Auto MW SCAN
Memory Clear details.