5
RECEIVE FUNCTIONS
D D Scope set mode (continued)
Peak Excursion
Set the next peak excursion level from 0 to 80 dB in
1 dB steps. (default: 6 dB)
If the difference between the signal peak and adja-
cent minimum values is less than the set level, it will
not be found as the next peak level when [NEXTΩ] or
[NEXT≈] is pushed.
Peak Threshold
Set the next peak threshold level from 0 to –100 dB
in 1 dB steps. (default: –90dB)
If the difference between the signal and last peak sig-
nal values is more than the set level, it will not be
found as the next peak level when [NEXTΩ] or
[NEXT≈] is pushed.
6dB
–90dB