6—VGA Main Display CH VIEW Screens
Channel-Specific Parameter Strips
At the left side of each CH VIEW screen is a strip that contains parameters specific to
the selected type of channel.

Input Channel Parameter Strip

1. Channel Name
2. PATCH BAY Selector
Click PATCH BAY to reveal a menu from which you
can select the source of the channel's input signal.
Inputs are always assignable in pairs, with odd-numbered inputs
being assignable to odd-numbered input channels, and so on.
3. PHANTOM Switch
Click PHANTOM—so it's lit—to turn on the
corresponding XLR input jack's phantom power.
4. PHASE Button
Click PHASE—so it's lit—to reverse the phase polarity of the
channel's signal.
5. ATT Knob
To adjust the level of the input signal coming into the input channel,
drag the ATT knob up or down as desired—the readout beneath the
knob shows the current amount of attenuation.
6. GROUP Selector
To assign the input channel to a fader group, click GROUP and
select the desired fader group from the pop-up menu.
7. CH LINK Button
To link the channel to its odd/even partner so that any changes
made to one channel affect both, click CH LINK to turn it on.
8. FDRLINK Button
Click FDRLINK—so it's lit—to link the current channel's fader to its
odd/even partner so their levels can be set by moving either fader
while their other parameters remain independently controllable.
9. AUTOMIX STATUS Button
Click the AUTOMIX STATUS button to set the channel's status
when Automix is turned on.