Pin Out Summary; Conference Link2 - Polycom SoundStructure C16 Hardware Installation Manual

Hide thumbs Also See for SoundStructure C16:
Table of Contents

Advertisement

Hardware Installation Guide for the Polycom SoundStructure C16, C12, C8, and SR12

Pin Out Summary

Warning

Conference Link2

3 - 4
Drawings and part numbers are provided for reference only. Other than cables
provided by Polycom, Polycom claims no responsibility or liability for the quality,
performance, or reliability of cables based on these reference drawings. Contact a
Polycom reseller to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for particular applications.
To build a custom Conference Link2 cable, use shielded CAT5e, or better, and
terminate both end connectors, P1 and P2, with standard 8P8C plugs (for
example, RJ45) using the wiring connections shown in the following figure.
The maximum length for this cable is 100 feet (30 m). Note that this cable
provides a cross-over connection between pins 1 and 2 and pins 5 and 6.
8
1
COLOR
WHITE/GREEN
GREEN
WHITE/ORANGE
ORANGE
WHITE/BROWN
BROWN
DRAIN WIRE
SHIELD
P1 - RJ-45 shielded Keystone jack, L-com RJ110C5-S or equivalent,
or
P1 - RJ-45 shielded plug, Tyco 5-569552 or equivalent with shielded RJ-45 panel
coupler kit (L-com ECF504-SC5E or equivalent).
P2- RJ-45 shielded plug, Tyco 5-569552 or equivalent.
P1
AWG
P1
24
1
24
2
24
5
24
6
24
7
24
8
24
3
SHELL
1
8
P2
P2
5
6
1
2
7
8
3
SHELL