Polycom SoundStructure C16 Hardware Installation Manual page 34

Hide thumbs Also See for SoundStructure C16:
Table of Contents

Advertisement

Hardware Installation Guide for the Polycom SoundStructure C16, C12, C8, and SR12
3 - 2
Thermal
Thermal Dissipation (Btu/hr): 266 Btu/hr (C16), 230 Btu/hr (C12), 215
Btu/hr (SR12), 200 Btu/hr (C8)
Operating temperature 0 - 40° C (104° F)
Operating temperature ranges for the three thermal sensors located on the
SoundStructure device are shown in the following table. These sensor values
are found on the Wiring page within SoundStructure Studio when connected
to a SoundStructure device. Green indicates normal operation up to the
temperatures listed in the following table. Yellow indicates an elevated
temperature that is acceptable but the ambient temperature and airflow in the
system should be checked. Red indicates an over-temperature event that must
be corrected for proper operation of the SoundStructure device.
Sensor
Normal (Green)
1
2
3
Inputs
Phantom power: 48 V DC through 6.8 kOhm series resistor per leg, 7.5 mA
per channel, software selectable
Analog input gain: -20 to 64 dB on all inputs in 0.5 dB steps, software
adjustable
Maximum input amplitude: +20.4 dBu, 1% THD + N
Nominal level: 0 dBu (0.775 Vrms)
Equivalent input noise: <-122 dBu, 20-20,000 Hz, Rs=150 Ohms (1%)
Input impedance: 10 kOhms
Input EMI Filter: Pi filter on all audio inputs
Outputs
Output gain: -100 to 20 dB in 1 dB steps, software adjustable
Maximum output amplitude: +23 dBu, 1% THD + N
Nominal output level: 0 dBu (0.775 Vrms)
Output impedance: 50 Ohm, each leg to ground, designed to drive loads >
600 Ohms
Output EMI filter: Pi filter on all audio outputs
Warning (Yellow)
° C
50
59
° C
69
79
° C
53
58
Error (Red)
° C
° C
60+
° C
° C
80+
° C
° C
59+

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Soundstructure sr12Soundstructure c12Soundstructure c8

Table of Contents