Elevation System Calibration - Landice 8700 Series Service Manual

Home and commercial treadmill
Table of Contents

Advertisement

MAX
STEP 2:
Turn machine on, increase speed until 1.2 mph
shows on display,
the display shows exactly 1.0 mph.
STEP 3:
Adjust "MIN" pot on KBLC-118 until belt
speed is between
8.8 - 9.3 rpm counting belt revolutions.
STEP 4:
Turn speed up to 8.8 mph ( on display ),
then slowly increase
exactly 9.0 mph.
STEP 5:
Adjust "MAX" pot on the KBLC-118 until the belt
speed is between
83.0 - 83.4 rpm ).
STEP 6:
Since the "MAX" and "MIN" pots will affect each
other during the
steps 2 - 5 several times.
needs readjustment.
Appendix 2:
Note:
The elevation system will need to
be re - calibrated:
1.
motor.
2.
potentiometer.
3.
inaccurate.
STEP
Remove the two screws holding the elevation
1:
potentiometer
and pull the pot from the back of the
elevation motor.
STEP
Turn the treadmill on in the diagnostic
2:
mode by holding down the " Select
MIN
then slowly decrease speed just until
0.95 - 1.00 mph using a tachometer OR
speed just until display shows
8.95 - 9.00 mph ( or
adjustment, it may be nessary to repeat
Continue calibration until neither pot

Elevation System Calibration

After replacing the elevation
After replacing the elevation
If the elevation readout appears
IR
CL
75

Hide quick links:

Advertisement

Table of Contents
loading