Channel Number
Function
1
Arm/Disarm/Panic
2
Silent Arm-Disarm/Remote Override/Trunk Release
3
Remote engine start or other accessories
4
Arm only
5
Disarm only
6
Panic only
7
Auto-learn Standard Configuration*
8
Auto-learn Single Button Arm/Disarm Configuration*
9
Delete all remotes
* * N N O O T T E E : : For Auto Learn Configurations, see Remote Configurations section of this guide.
4.
Press the remote button: While holding the Override switch, press the button
from the remote that you wish to assign to the selected channel. The unit will chirp indi-
cating successful programming. It is not possible to teach a remote button to the sys-
tem more than once.
Channels #4-6: Channels 4 through 6 are used to assign the arm, disarm and panic functions to sep-
arate buttons on the remote control. Teaching a button to Channel 4 erases all information about that
remote from memory. Any auxiliary functions that are desired will have to be reprogrammed. Similarly,
if the remote is set up to use the separate arm, disarm and panic channels and a button from that
remote is entered into channel one, the remote will be erased from memory, and the system will only
recognize the button that was entered into channel one.
Channel #9: If any button from a known remote is programmed to Channel 9, all remotes will be
erased from memory and the system features will revert to the default settings. This is useful in cases
where the one of the customer's remotes is lost or stolen. This will erase any lost or stolen remotes from
the system's memory. It can also be used to start from scratch if the remote buttons were programmed
incorrectly.
Release. Once the code is learned, the Override switch can be released.
5.
To exit the learn routine:
One long chirp indicates that Programming Routine has been exited. Programming Routine will be exit-
ed if any of the following occurs:
Ignition is turned off.
Door is closed.
Override switch is pressed too many times.
More than 15 seconds elapse between steps.
20
Wire Color
RED/WHITE
WHITE/BLUE

Hide quick links: