Troubleshooting - Schwinn 420 Elliptical - 2010 Model Owner's Manual

Owner's manual
Hide thumbs Also See for 420 Elliptical - 2010 Model:
Table of Contents

Advertisement

Available languages

Available languages

Problem
No display / not fully displayed / unit will
not turn on
The Unit operates but Telemetric HR not
displayed
Console displays "E2" error code
No speed / RPM reading, Console
displays "E3" error code

Troubleshooting

Check
Electrical (wall) outlet
The Connection at front of unit
Main console cable integrity
Main console cable connections /
orientation
Console display for cracks or other
damage
Display
Chest Strap
Interference
The Chest Strap
Check data cable integrity
Check data cable
connections/orientation
Console Electronics
Main Console cable integrity
Main Console cable connections /
position
The Magnet position (requires shroud
removal)
RPM Sensor (requires shroud removal)
18 18 18
Solution
Use a correctly operating outlet.
Connection must be secure and not
damaged. Replace adapter or connection
at unit if damage shows.
Replace the cable if the wires are
crimped or cut.
Make sure the cable is connected
correctly behind the Console and at the
base of the Console Mast.
Replace the Console if damaged.
Replace the computer if the Console
does not fully display.
Make sure that the strap is directly
against skin and contact area is moist.
The Strap must be Polar® compatible.
Move the unit away from sources of
interference (TV, Microwave, etc).
Connect the strap to a functioning Polar®
compatible device to see if it works. If
it does not function, replace the strap.
If strap works with other devices but
not with the elliptical, replace the HR
receiver.
All wires in cable should be intact. If any
are cut or crimped, replace cable.
Insure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
If tests reveal no other issues, Console
should be replaced.
All wires in cable must be intact. Replace
the cable if the wires are crimped or cut.
Make sure the cable is correctly
positioned and connected. The small
latch on connector must line up and click
into position.
Replace the Flywheel or full primary
assembly if you do not see a magnet.
RPM sensor must be aligned with magnet
and connected to data cable. Re-align
sensor if necessary. Replace if there
is any damage to sensor or connecting
wire.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

420