CC488 | Quick Reference Guide | 2.0 Programming Parameters
2.6.2

Zone Types

Zone Type
Description
0
Instant
1
Handover
2
Delay-1
3
Delay-2
4
Reserved
5
Reserved
6
24 hr. Medical
7
24 hr. Panic
8
24 hr. Hold-up
9
24 hr. Tamper
10
Reserved
11
Keyswitch
12
24 hr. Burglary
13
24 hr. Fire
14
Chime
15
Not Used
2.6.3

Zone Pulse Count

Use the pulse count to program how many pulses
(0 to 15) need to be registered within the pulse
count time to activate an alarm.
2.6.4

Zone Pulse Count Time

Option
20 ms Loop
Response Time
0
0.5 sec.
1
1 sec.
2
2 sec.
3
3 sec.
4
4 sec.
5
5 sec.
6
10 sec.
7
15 sec.
2.6.5

Zone Options 1

Option
Description
1
Lockout siren/dialler
2
Delay Alarm report
4
Silent alarm
8
Sensor watch
2.6.6

Zone Options 2

Option
Group
1
Isolated in STAY Mode 1
2
Zone isolation allowed
4
Forces arming allowed
8
Zone Restore Report allowed
2.6.7

Zone Dialler Options

Option
Description
0
No zone reports allowed
1
Report to Receiver 1
2
Report to Receiver 2
4
Report to both Receiver 1 and Receiver 2
8
Report to Receiver 2 only if Receiver 1 fails
Bosch Security Systems | 6/04 | 4998152446B
Option
150 ms Loop
Response Time
8
20 sec.
9
30 sec.
10
40 sec.
11
50 sec.
12
60 sec.
13
90 sec.
14
120 sec.
15
200 sec.
2.6.8

Keyswitch Zone Options

The keyswitch zone options replace Zone Options
1 only for the zones that were programmed to
operate as a keyswitch zone.
Option
Description
0
Latching arm and disarm in AWAY Mode
1
Latching arm in AWAY Mode
2
Latching disarm from AWAY Mode or STAY Mode
4
Latching arm and disarm in STAY Mode
5
Latching arm in STAY Mode
6
Latching disarm from STAY Mode
8
Momentary arm and disarm in AWAY Mode
9
Momentary arm in AWAY Mode
10
Momentary disarm from AWAY Mode or STAY
mode
12
Momentary arm and disarm in STAY Mode
13
Momentary arm in STAY Mode
14
Momentary disarm from STAY Mode
2.7

Swinger Programming

2.7.1

Swinger Shutdown Count For Siren

Location
323
Default
3
0
Unlimited
1 to 15
Number of times siren operates until lockout
2.7.2

Swinger Shutdown Count For Dialler

324
Location
Default
6
0
Unlimited
1 to 15
Number of times dialler operates until lockout
2.8

Zone Status Programming

2.8.1
Zone Status – Zone Tamper Report
325 to 326
Location
Zone Tamper Report
Zone Tamper Restore Report
2.8.2
Zone Status – Walk Test Report
Location
327 to 328
Walk Test Start Report
Walk Test End Report
2.8.3
Zone Status – Bypass Report
Location
329 to 330
Zone Bypass Report
Zone Bypass Restore Report
2.8.4
Zone Status – Trouble Report
331 to 332
Location
Zone Trouble Report
Zone Trouble Restore Report
EN | 14
Location
Default
325
0
326
0
Location
Default
327
0
328
0
Location
Default
329
9
330
8
Location
Default
331
2
332
3