Advertisement

Adjustment
Reference
Designator
Procedure
For
3-16 Adjustments
Range of Values
100 Kl to 1M
0 to 100
3.83 K to 9.09 K
909 to 2.37 K
3.16 K to 8.25 K
100 K to OPEN
100 K to OPEN
10 K to OPEN
3.83 K to 9.09 K
3.16 K to 8.25 K
6.81 K to 10.0 K
38.3 K to 56.2 K
28.7 K to 42.2 K
6.19 K to 9.09 K
1.96 K to 2.87 K
82.5 K to 147 K
261 K to 464 K
56.2 K to 100 K
562 K to 1M
46.4 K to 82.5 K
316 K to 562 K
422 K to 750 K
619 K to l.lM
90.0 K to 162 K
61.9 K to 110 K
2.15 K to 8.25 K
42.2 K to 100 K
75 K to 178 K
10.0 K to 17.5 K
100 to 5.11 K
Serial Prefix 2813A to 2816A,
see the back of this table for exceptions to A4A9.
Function of Component
Sets adjustment range of LC amplitude.
Adjusts bandwidth shape in 10 kHz bandwidth.
Adjusts crystal filter bandwidth.
Adjusts LC mode feedback.
Adjusts LC filter bandwidth.
(85662-60131 only)
(85662-60190 only)
Adjusts crystal filter bandwidth.
Adjusts LC filter bandwidth.
Sets TC of 3 kHz RBW
Sets TC of 10 kHz RBW
Sets TC of 300 kHz RBW
Sets TC of 1 MHz RBW
Sets TC of 3 MHz RBW
Sets 1.0 dB step size
Sets 0.2 dB step size
Sets 1.2 dB step size
Sets 0.4 dB step size
Sets 1.8 dB step size
Sets 0.6 dB step size
Sets 0.8 dB step size
Sets 0.1 dB step size.
Sets 1.6 dB step size.
Sets 1.4 dB step size.
Centers 3 kHz BW adjustment range.
Centers 10 kHz BW adjustment range.
Centers 300 kHz BW adjustment range.
Centers 1 MHz BW adjustment range.
Centers 3 MHz BW adjustment range.