NEC Express 5800 User Manual page 111

Hide thumbs Also See for Express 5800:
Table of Contents

Advertisement

IMPORTANT: If the message, "Windows - FT Orphaning A disk that is part of a
fault-tolerant volume can no longer be accessed" is displayed during the update
process, an OS stop error may occur when restarting the OS. If an OS stop error occurs,
perform the following procedures. In this case, the system will be successfully updated,
however,
disk mirroring is disabled. Make sure to check disk mirroring in step 7.
1) Power off the system by pressing and holding the POWER switch.
2) Make sure that the two BMC status LEDs of the PCI modules (for Group1/ Group2) are
turned off.
While the BMC status LED is red blinking, do not perform step c) and the followings.
Otherwise the BMC firmware may become damaged.
3) Identify the PCI module where POWER switch is lit green.
Remember which PCI module's POWER switch (for Group1 or Group2) is lit green.
Unplug the power cord connected to the following AC inlet.
See the rear view of this product in page 3-13 for the location of the AC in
- If PCI module (for Group1)'s POWER switch is lit gre
Unplug the power cord connected to "AC inlet B" on the rear of machine. (AC
inlet on the above. See page 3-13 for
- PCI module (for Group2)'s POWER switch is lit gree
Unplug the power cord connected to "AC inlet A" on the rear of machine. (AC
inlet on the bottom. See page 3-13 for
4) Check that the POWER switch of the other PCI module is lit green.
If it is not lit green, do the procedures from step b) again.
5) Plug the power cord which was unplugged in step c) again.
6) Make sure that the two BMC status LEDs of the PCI modules (for
Group1/for Group2) are turned off, and proceed to step g
While the BMC status LED is red blinking, do not perform steps g) and the followings.
Otherwise the BMC firmware may become damaged.
7) Press the POWER switch of PCI module which is lit green. Then, power on the system.
7.
Check disk mirroring.
If the disk mirroring is disabled, enable the mirroring again.
IMPORTANT:
resynchronization is completed.
During disk re-synchronization, do not shut down the system until the
Troubleshooting
en,
details.)
n,
details.)
).
5-13
let.