Starting The Task; Selecting The Dimm Memory Module Slot - Fujitsu PRIMERGY RX900 S1 Maintenance Manual

Fujitsu server user manual
Table of Contents

Advertisement

Main memory
9.3.2

Starting the task

Ê Perform the following procedures:
1.
"Opening the rack door" on page 40
2.
"Shutting down the server" on page 41
3.
"Sliding the server out of the rack" on page 42
4.
"Opening the server" on page 44
5.
"Removing the CPUMEMR" on page 190
9.3.3

Selecting the DIMM memory module slot

Ê Choose the DIMM memory module slot according to the configuration rules
summarized in this section. For detailed information see "Baseboard D3081,
CPUMEMR D3131, PCIR D3082 for PRIMERGY RX900 S1 Technical
Manual".
CPUMEMRs are populated in four steps. In each step, four DIMM memory
modules are added. At least four DIMM memory modules must be installed on
CPUMEMR #1 and #2. CPUMEMRs #3 to #8 can be left empty.
table 4
show the population order for DIMM memory modules.
192
Maintenance Manual
figure 113
and
RX900 S1