Using The Prtdiag Command; Options - Fujitsu SPARC ENTERPRISE M4000 Service Manual

Fujitsu computer hardware user manual
Hide thumbs Also See for SPARC ENTERPRISE M4000:
Table of Contents

Advertisement

2.7.2

Using the prtdiag Command

The prtdiag command displays configuration and diagnostic information. The
diagnostic information identifies any failed component.
The prtdiag command is located in the /usr/platform/platform-name/sbin/
directory.
Note – The prtdiag command might indicate a slot number different than that
identified elsewhere in this document. This is normal.
2.7.2.1

Options

TABLE 2-13
help troubleshooting.
Options for
TABLE 2-13
Option
Description
No option
Lists components.
Verbose mode. Displays the
-v
time of the most recent AC
power failure and the most
recent hardware fatal error
information.
2-28
SPARC Enterprise M4000/M5000 Servers Service Manual • August 2009
describes options for the prtdiag command and how those options can
prtdiag
How It Can Help
Identifies CPU timing and PCI cards installed.
Provides the same information as no option. Additionally
lists fan status, temperatures, ASIC, and PROM revisions.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m5000

Table of Contents